Smart Clamps GLC02
Table 1
SN
Green LED
1
ON
2
Flash
3
ON
4
OFF
5
OFF
6
OFF
OVERRIDE function: When the clamps does detect any signals from car battery, you may use this
function for jump start by push & hold the button on the side of smart clamps for 5s to activate.
Make sure connection is correct before this operation.
WARNING: The OVERRIDE function will void all protections temporarily, so please make sure the
red and black clamps are correctly connected to a 12V battery.

4.4 USB output

1. Connect the USB cable to the USB output port of the device (3);
2. Short press the "POWER" button (7), USB provides 5V2.4A output to provide charging for mobile
phones/tablets and other electronic products.
3. The USB output will be automatically turned off after charging is completed.
Red LED
Audible Warning
OFF
OFF
OFF
OFF
Flash
ON
Flash
OFF
Flash
ON
ON
ON
Status and Solutions
Correct status for jump start. Proceed to start
the car.
If not started, make sure the car light is turn off
and connect again.
1) No car battery connected or detected
2) Reverse charge protection
3) Time out cut off
Solution: Re-connect the clamps for jump start.
Input over voltage protection
Low battery protection.
Solution: recharge the jump starter to full
1) Wrong connection to high voltage. Slow flash.
2) Reverse polarity connection protection. Fast
flash.
3) Short Circuit protection
Solution: Follow manual for jump start and re-
connect.
Over temperature protection.
Solution: Wait 5-10 minutes to cool down
before next jump start.