Troubleshooting; Audit - probst AIRLIFT ALX-120 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 56

Troubleshooting

7
Troubleshooting
7.1

Audit

The audit should always be carried out with two persons!
Place the vacuum lifting device on a concrete or tiled surface.
Switch on the vacuum and check whether a vacuum underpressure is reached.
If no vacuum is achieved, clean the dirt strainer and try a new suction plate or silicone foam gasket.
When a vacuum underpressure is reached, make sure that the suction release lever is working properly.
If routine maintenance cannot restore the lost suction power, have the vacuum lifting device serviced by a qualified
technician.
7.1.1
Troubleshooting:
Low suction or poor pick-up
Possible causes:
Airway blocked
Disposable paper filter is full or wet
Damaged or unconnected hoses
Dirty or damaged suction plate seal
Damaged suction plate
Vacuum motor does not work
Possible causes:
Vacuum generator is not plugged in1
Failure of the socket or the ON/OFF
switch
Thermal protection of the motor
activated
Engine damaged
Failure of vacuum pump due to wetness
52600018
Remedial action:
Check and remove any obstructions to the airflow.
Replacing the disposable paper filter.
Make sure that all hoses are not damaged and are connected
correctly.
Wash or replace the seal. Use only soap and water for cleaning.
Use a different suction plate or send the suction plate to the
manufacturer for replacement.
Remedial action:
Check that the vacuum generator is plugged in correctly.
Check all connections and reset all circuit breakers. Check circuit with
another functioning tool.
Check if the air flow is obstructed. Allow vacuum generator to cool
down for 60 minutes before continuing operation.
Return to the manufacturer.
Before sucking in the load, remove water from the suction surface.
Before switching off the vacuum generator (with the vent flap open),
let it run dry for at least 1 minute.
16 / 17
GB

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido