NOTE: This tool features a power regulator
valve. First press the air � ow regulator (D)
downward and then slowly turn it either
clockwise or counterclockwise to have either
of the settings pointed at the triangle mark
on the housing.
"Setting 1" is the least amount of power,
which is suitable for just mounting threaded
fasteners on workpiece while "Setting 4"
is the most amount of power, which is for
tightening threaded fasteners on workpiece.
Choose the correct torque needed on
workpiece when mounting or releasing
threaded fasteners by turning the air � ow
regulator. (See Figure 6)
Figure 6
Care and maintenance
The tool should be lubricated daily (or before
each use) with air tool oil (not included).
SAE 10W oil or sewing machine lubricant or
any other high grade turbine oil containing
moisture absorbent, rust inhibitors, metal
wetting agents and an EP (extreme pressure)
additive may be used as a substitute. Do not
use detergent oil.
During continuous operation, the tool should
be oiled every 1 to 2 hours. This may be done
using an in-line oiler, or manually. If done
manually, proceed as follows:
1. Disconnect the tool from air supply. (See
Figure 7)
Figure 7
2. Place a few drops of air tool oil into the
air inlet. (See Figure 8)
Figure 8
GB
57