5.2 Connecting electrical supply
WARNING
Before installing, turn power OFF at the service panel.
Lock service panel to prevent power from being turned
ON accidentally.
To reduce the risk of electrical shock and fire, do not use a
flexible power-supply cord with this appliance. Connect
only to a 3-wire, 120/240-Volt power supply; the neutral
conductor is not required for the operation of the appli-
ance. The voltage at the power supply electrical connec-
tions shall be 150-volts-to-ground or less.
Requirement: The electrical power supply system should
be a 1-phase, 3-wire system with ground connection.
Install a suitable junction box (not furnished).
1.
– An appropriately-sized, UL-listed conduit connector
must be used to correctly attach the conduit to the
junction box.
– The branch-circuit breakers ampacity, the wire sizes
and the connections must conform to the require-
ments of the National Electrical Code or Canadian
Electrical Code and all local codes and ordinances.
Attach the flexible conduit to the junction box. Metal
2.
conduit and leads are factory installed.
Connect the cooktop lead wires to the junction box sup-
3.
ply wires in proper phase.
– black (L1) to black
– red (L2) to red
– green or blank copper wire to ground
6 Checking the installation

Checking the installation

Check if your unit is working properly after you have com-
Checking the installation
pleted the installation steps.
WARNING
Before you turn on power supply, make sure all controls
are in the OFF position.
Remove everything from the cooktop surface including
1.
stickers.
Clean the cooktop surface with cooktop cleaning cream.
2.
Switch on the circuit breaker.
3.
Verify that all cooking zones function properly.
4.
8
240 V AC, 60 Hz system: circuit
breaker
40 Amp
40 Amp
50 Amp
50 Amp
40 Amp
40 Amp
30 Amp
40 Amp

Customer Service

7 Customer Service
If you have any questions on use, are unable to eliminate
Customer Service
an issue in the appliance yourself, or the appliance needs
to be repaired, please contact our Customer Service.
With any warranty repair, we will make sure your appli-
ance is repaired by an authorized service provider using
genuine replacement parts. We use only genuine replace-
ment parts for all repairs.
Detailed information on the warranty period and terms of
warranty can be found in the Statement of Limited Product
Warranty, from your retailer, or on our website.
If you contact the Customer Service, you will need the
model number (E-Nr.) and the production number (FD) of
your appliance.
USA:
1-800-944-2904
www.bosch-home.com/us/owner-support/get-support
www.bosch-home.com/us/shop
CA:
1-800-944-2904
www.bosch-home.ca/en/service/get-support
www.bosch-home.ca/en/service/cleaners-and-accessories
7.1 Model number (E-Nr.) and production
You can find the model number (E-Nr.) and the production
number (FD) on the appliance's rating plate.
Making a note of your appliance's details and the Cus-
tomer Service telephone number will enable you to find
them again quickly.
7.2 Rating plate location
You can find the rating plate of your appliance:
¡ on the underside of the appliance
¡ in the appliance pass
208 V AC, 60 Hz system: circuit
breaker
30 Amp
30 Amp
40 Amp
40 Amp
40 Amp
40 Amp
30 Amp
40 Amp
number (FD)