Secure regulator to cooktop gas inlet using approved
®
Teflon
tape. Turn to hand tighten plus 1/4 turn, not
exceeding one turn for alignment.
Turn on gas at shut-off valve and check supply line con-
nections for leaks using a soap solution. Do not use a
flame of any sort.
Important Notes for Gas Connection:
The appliance and its individual gas shutoff valve must
be disconnected from the gas supply piping system dur-
ing any pressure testing of that system at test pres-
sures in excess of 1/2 psi (3.5kPa).
The appliance must be isolated from the gas supply pip-
ing system by closing its individual manual shut-off valve
during any pressure testing of the gas supply piping sys-
tem at test pressures equal to or less than 1/2 psi
(3.5kPa).

HIGH ALTITUDE INSTALLATION

NOTE: This cooktop has been CSA certified for safe
operation up to a height of 10,000 ft. without any
modifications to components for natural gas or after
LP conversion.
For technical service questions contact Customer Service at 800/944-2904.
For the most up to date critical dimensions by fax, use your fax handset and call 775-833-3600.
We reserve the right to change specifications or design without notice. Some models are certifled for use in Canada. BSH Home
Appliances Corp. is not responsible for products which are transported from the U.S. for use in Canada. Check with your local
Canadian distributor or dealer.
Note: The Bosch cooktop referred to throughout this manual is manufactured by BSH Home Appliances Corp.

For Massachusetts Installations:

1. Installation must be performed by a qualified
or liscenced contractor, plumber or gas fitter
qualified or liscensed by the state, province or
region where this appliance is being installed.
2. Shut-off valve must be a "T" handle gas cock.
3. Flexible gas connector must not be longer
than 36 inches.

5. Connect Electrical Supply

Before connecting 5-foot supply cord to wall recep-
tacle, make certain that gas shutoff valve and all burner
controls are in OFF position.

6. Final Check

After electrical connection is complete, place each
burner cap in correct notched position and check op-
eration of electric igniters. Check flame characteristics.
Flame should be blue with no yellow tip.
Check Use & Care manual for troubleshooting infor-
mation.
Use code # 8317.
5551 McFadden Avenue, Huntington Beach, CA 92649 • 800/944-2904
© 2002 BSH Home Appliances Corp. • Litho/U.S.A. 06/03
PAGE 4
50 60 00 36 17 (8205) Rev B