• Disconnect the spray gun (24) from the high pressure hose (35) and put it away using the supports (3).
• Disconnect the high pressure hose from the water outlet fitting (16), wind it up carefully, avoiding
bends and put it away.
• Wind the power cable up with care (6), avoiding bending it and put it away.
• The high pressure cleaner must be kept in a dry, clean place paying attention not to damage the high
pressure hose and the power cable. Engage the brake (20) to avoid any uncontrolled movements of
the machine.
NOTE: after a prolonged period of non-use you could find a few drops of water under the pump.
This dripping normally disappears after a few hours of use. If it does persist however, contact a Specialized
Technician.
Do the operations described in the "Stop" paragraph and follow the instructions given in the following
table.
MAINTENANCE
SCHEDULE
Every time it is used
Weekly
Monthly
CAUTION
• When working, the high pressure cleaner should not be too noisy and there should be no obvious
drips of water or oil underneath it. If this is the case have the machine checked by a Specialized
Technician.
24
DECOMMISSIONING
ROUTINE MAINTENANCE
• Check the power cable, high pressure hose, fittings, spray gun and lance hose.
If one or more parts are found to be damaged do not, under any
circumstances, use the high pressure cleaner and contact a Specialized
Technician
• Check pump oil level with the motor off and the machine completely cooled
down.
• Use the indicator (50) (INDO - LENA) or the dipstick integrated in the
plug (14) (INDO). When topping up is needed please refer to the lubricant
types given in the "Specifications and technical data" paragraph.
• Clean the water inlet filter (18).
Unscrew the cap (28) with a 27 mm (INDO) fixed jaw spanner and take the
cartridge (27) out, (see Fig. 4). It is normally enough to put the cartridge under
running water or blow it with compressed air to clean it. In the most difficult
cases, use a scale remover or replace it, contacting an authorised assistance
centre to buy the new cartridge.
Mount the cartridge and screw the plug back down.
• Clean the water inlet filter (18): refer to what has been explained previously.
• Clean the nozzle.
It is normally enough to put the pin (31) supplied through the hole of the
nozzle to clean it. If the results are not good, replace the nozzle purchasing it
from an authorised assistance centre.
The nozzle can be replaced using a 14 mm box spanner (not supplied).
• Check soundness of the water inlet and outlet circuits.
• Check clamping of the pump to the engine and the engine to the frame.
If clamping is found to be insecure do not, under any circumstances, use
the high pressure cleaner and contact a Specialized Technician.
JOB