1. Unscrew the telescopic pipe.
2. Remove the water feature nozzle.
3. Clean the telescopic section and water feature nozzle under running water.
1. Take the pump out of the water.
2. Remove the outlet spigot with the hose.
3. Unscrew the telescopic pipe.
4. Open the filter housing by pressing in the two side latches at the same time (
5. Take off the housing cover (
6. Press the unlocking head (
7. Pull the pump forwards out of the guide (
8. Clean the filter housing with a water jet.
9. Install the pump again in reverse order.
When assembling, make sure that the mains cable is guided correctly through the strain relief and the
housing opening (
Cleaning the pump (1000 / 1500)
1. Open the filter housing (
2. Unscrew the locking ring ② from the motor housing ① (
3. Use a screwdriver to carefully prise the pump cover ⑤ uniformly to the front out of the motor hous-
ing.
4. Pull the impeller ④ out of the motor housing.
5. Install the pump again in reverse order.
▶ When assembling, make sure that the bearing bushings ③ are inserted correctly in the pump cover
and in the motor housing.
▶ When assembling, make sure that the locking ring engages easily when being screwed on.
Cleaning the pump (2500 / 3500)
1. Open the filter housing (
2. Unscrew the locking ring ② from the motor housing ① (
3. Use a screwdriver to carefully prise the pump cover ⑤ uniformly to the front out of the motor hous-
ing.
4. Pull the ceramic axis ④ and the impeller ③ out of the motor housing.
▶ The ceramic axis is fragile. Therefore, handle the ceramic axis very carefully.
5. Install the pump again in reverse order.
‧ When assembling, make sure that the lugs on the pump cover engage in the recesses in the motor
housing.
‧ When assembling, make sure that the locking ring engages easily when being screwed on.