WARNINGS
• TO AVOID FIRE, SHOCK, OR DEATH, UNPLUG CORD OR TURN OFF POWER
AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF
BEFORE WIRING!
• This device is not to be used, directly or indirectly, with a life-support apparatus or
associated circuitry. Use this device only on a grounded circuit, protected by a fuse
or a circuit breaker.
• To be installed and/or used in accordance with appropriate electrical codes
and regulations.
• If you are not sure about any part of these instructions, consult an electrician.
TO INSTALL
1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH, UNPLUG CORD OR
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE
POWER IS OFF BEFORE WIRING!
2. Wire device only with 3 conductor cords of the following type: UL Types – SJTW,
SJOW, SJTOW, SJTOOW, SJEOW, STW, STOW and STOOW.
ASSEMBLY PROCEDURE:
(a) The Self-Test GFCI in-line device's LINE side should be connected to the cable
with the male plug.
(b) Depending upon the cable outer jacket diameter, choose a grommet and clamp
size from the Table - Grommet and Clamp Size. This table indicates the
correct grommet and clamp size to be used for specific cable sizes/types.
(c) Slip grommet over cord outer jacket at least 1.5 inches.
(d) Remove outer jacket of cord 7/8 in. (2.2cm) from end.
(e) Strip each conductor 23/64 in. (0.91 cm) and twist strands tightly together.
DO NOT TIN ENDS.
(f) Insert wire-stripped ends under the appropriate terminal clamps: BLACK wire
under the BRASS screw, WHITE wire under the SILVER screw, and GREEN
wire under the GREEN screw. Torque each wire terminal screw between 10 to
14 in-lbs. DO NOT OVER-TIGHTEN.
(g) Move grommet along cord to proper location and into sealing well.
(h) Attach cord clamp (observe clamp orientation as shown in Diagram 1). Outer
cord jacket must extend fully under cord clamp. Torque each cord clamp
screw between 15 to 20 in-lbs. DO NOT OVER-TIGHTEN.
(i) Place back cover in position. Torque each back cover screw between 12 to 18
in-lbs. DO NOT OVER-TIGHTEN.
TEST INSTRUCTIONS FOR GFCI
1. Plug device into energized receptacle.
a. Auto-Reset Devices: GREEN power indicator LOAD goes ON. If the fault status indicator light turns ON or
continuously blinks RED, or if the GFCI cannot reset, go to the Self-Test Operation section.
b. Manual-Reset Devices: Press TEST/RESET button and release. GREEN power indicator LOAD goes ON. If the
fault status indicator light turns ON or continuously blinks RED, or if the GFCI cannot reset, refer to the Self-Test
Operation section.
2. PressTEST/RESET button. Power indicator LOAD must go OFF.
3. Press TEST/RESET button and release. Power indicator LOAD must go ON for use.
CAUTION: DO NOT USE THIS DEVICE IF ABOVE TEST FAILS. TEST UNIT BEFORE EACH USE. DO NOT TEST THIS
UNIT WITH THE CONNECTED LOAD IN THE "ON" POSITION.
SELF-TEST OPERATION
A Self-Test GFCI has all the features of a conventional GFCI cord set. In addition, this GFCI tests itself periodically
to confirm that the GFCI electronics are functional. The LOAD indicator light will be solid GREEN when the GFCI is
powered from the LINE side and working correctly.
Self-Test Indications: If the fault indicator light is solid or continuously flashing RED, a problem may exist. Press the
TEST/RESET button to trip the GFCI. If unable to reset, replace the GFCI.
NOTE: The fault status indicator may flash RED at power "ON" and reset.
Ring Seal Position
Position de la
bague d'étanchéité
Posición del anillo de sellado
Inner seal
Joint interne
Sellado interno
Inner seal
Joint interne
Sellado interno
Patents covering this product, if any, can be found on Leviton.com/patents.
SmartlockPro
®
is a trademark of Leviton Manufacturing Co., Inc., registered in the United States, Canada, Mexico, and China.
FCC STATEMENT
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
IC STATEMENT
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada ULC to the attention of the Quality Assurance Department, 165 Hymus
Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper
use for two years from the purchase date. Leviton's only obligation is to correct such defects by repair or replacement, at its option. For details visit www.leviton.com or call 1-800-824-3005. This warranty
excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused,
opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including
merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a
particular purpose, is limited to two years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment,
lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
SmartlockPro
Fault Circuit Interrupter In-Line Device
Cat. No. GSIA2 (AUTO-RESET), Rated: 20A-120VAC, 60Hz, 2400W HP: 3/4
Cat. No. GSIM2 (MANUAL-RESET), Rated: 20A-120VAC, 60Hz, 2400W HP: 3/4
Diagram / Schéma / Diagrama
*NOTE: Cord jacket must extend fully under cord clamp
*REMARQUE : tout le pourtour de la gaine doit être sous le collier de cordon
*NOTA: El forro del cordón debe estar totalmente extendido debajo de la abrazadera
Screws
Vis
Tornillos
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
For Technical Assistance Call: 1-800-824-3005 (USA Only) or 1-800-405-5320 (Canada Only) www.leviton.com
Portable Self-Test Ground
®
CAUTIONS
• For Auto-Reset units GSIA2 ONLY: Power will automatically be applied to the load wires
when the device is energized.
• For Auto-Reset units GSIA2 ONLY: The connected load should be turned OFF during a
power failure as this device will automatically reset when power is restored. This device will
NOT automatically reset after a ground fault is detected while in use.
• This device protects against current leakage caused by ground faults only. It does not protect
against overcurrent or short circuits.
• This device is suitable for temporary outdoor use. DO NOT immerse this product in water.
• Your device may differ from the illustrations depicted.
• Plug this device directly into an outlet. DO NOT plug it into an extension cord.
• Use this device with copper wire only.
INSTALLATION INSTRUCTIONS
Wire Gauge
16
14
12
18
16
14
12
SMALL: 0.330 in. - 0.435 in.
Ring Seal
Bague d'etanchéité
Anillo de sellado
Cord Jacket
Gaine
Forro del cordón
Cord Clamp
Collier de cordon
Abrazadera del cordón
Table - Grommet and Clamp Size
No. of
Diameter
Maximum
Conductors
(nominal)
Current
WIRE TYPE SJ
3
0.330 in.
13-Amps
3
0.370 in.
15-Amps
3
0.435 in.
20-Amps
WIRE TYPE ST
3
0.365 in.
10-Amps
3
0.391 in.
13-Amps
3
0.550 in.
15-Amps
3
0.597 in.
20-Amps
ALLOWABLE CABLE OUTER JACKET DIAMETER FOR
GROMMET / CORD CLAMP:
MEDIUM: 0.550 in.
Diagram / Schéma / Diagrama
Back Cover / Coquille / Cubierta posterior
Screws / Vis /Tornillos
PK-A3381-10-02-2B
ENGLISH
Grommet
Cord Clamp
SMALL - I.D.
SMALL
0.210 in.
SMALL - I.D.
SMALL
0.210 in.
SMALL - I.D.
SMALL
0.210 in.
SMALL - I.D.
SMALL
0.210 in.
SMALL - I.D.
SMALL
0.210 in.
MEDIUM- I.D.
LARGE
0.310 in.
LARGE - I.D.
LARGE
0.475 in.
LARGE: 0.597 in.
FAULT
LOAD

Publicidad

loading

Resumen de contenidos para Leviton SmartlockPro GSIA2

  • Página 1 LIMITED 2 YEAR WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for two years from the purchase date.
  • Página 2 Mexique et en Chine. momento de su venta por Leviton está libre de defectos en materiales o fabricación por un período de dos años desde la fecha de la compra original. La única obligación de Leviton es corregir tales defectos ya sea con reparación o reemplazo, DÉCLARATION DE CONFORMITÉ...

Este manual también es adecuado para:

Smartlockpro gsim2