OBJ_BUCH-0000000351-002.book Page 18 Monday, April 1, 2019 2:55 PM
18 - English
Character
Unit of measurement,
international
f
Hz
-1
nS
/min, min
, rpm, r/min
°
kg
LpA
dB
LwA
dB
LpCpeak
dB
K...
2
m/s
m, s, kg, A, mm, V,
W, Hz, N, °C, dB,
min, m/s2
For your safety.
Read all safety warnings and all
WARNING
instructions. Failure to follow the
warnings and instructions may result in electric shock,
fire and/or serious injury.
Save all warnings and instructions for future reference.
Do not use this power tool before you have thor-
oughly read and completely understood this
Instruction Manual as well as the enclosed "General
Safety Instructions". The documents mentioned should
be kept for later use and enclosed with the power tool,
should it be passed on or sold.
Please also observe the relevant national industrial safety
regulations.
Intended use of the power tool:
Hand-guided oscillator for use without water supply in
weather-protected environments using the application
tools and accessories recommended by Berner.
– for cutting polyurethane beads for glazier work in
automobiles, lorries and busses
– for sawing out chassis sections and removing under-
seal materials
– for sanding of chassis parts
This power tool is not suitable for sawing wood and sim-
ilar materials.
This power tool is also suitable for use with AC genera-
tors with sufficient power output that correspond to the
Standard ISO 8528, design type G2. This Standard is par-
ticularly not complied with when the so-called distortion
factor exceeds 10 %. When in doubt, please refer to the
generator instruction/specification guide.
Special safety instructions.
Hold power tool by the insulated gripping surfaces, when
performing an operation where the cutting accessory
may contact hidden wiring or its own cord. Cutting acces-
sory contacting a "live" wire may make exposed metal
parts of the power tool "live" and could give the opera-
tor an electric shock.
Unit of measurement,
Explanation
national
Hz
Frequency
/min
Rated oscillation rate
°
Oscillation angle
kg
Weight according to EPTA-Procedure 01
dB
Sound pressure level
dB
Sound power level
dB
Peak sound pressure level
Uncertainty
2
m/s
Vibrational emission value according to
EN 60745 (vector sum of three directions)
m, s, kg, A, mm, V, W,
Basic and derived units of measurement from
Hz, N, °C, dB, min,
the international system of units SI.
m/s2
Use clamps or another practical way to secure and sup-
port the workpiece to a stable platform. Holding the
work by hand or against your body leaves it unstable and
may lead to loss of control.
Do not use accessories which are not specifically
designed and recommended by the power tool manufac-
turer. Safe operation is not ensured merely because an
accessory fits your power tool.
Grasp the power tool in such a safe manner that your
body never comes into contact with the application tool,
especially while working with application tools such as
saw blades or other blades pointed toward the grasping
range. Touching sharp tips or cutting edges can lead to
injuries.
Wear personal protective equipment. Depending on appli-
cation, use face shield, safety goggles or safety glasses.
Where appropriate, wear dust mask, hearing protectors,
gloves and workshop apron capable of stopping small
abrasive or workpiece fragments. The eye protection
must be capable of stopping flying debris generated by
various operations. The dust mask or respirator must be
capable of filtrating particles generated by your opera-
tion. Prolonged exposure to high intensity noise may
cause hearing loss.
Do not direct the power tool against yourself, other per-
sons or animals. Danger of injury from sharp or hot
application tools.
Do not rivet or screw any name-plates or signs onto the
power tool. If the insulation is damaged, protection
against an electric shock will be ineffective. Adhesive
labels are recommended.
Clean the ventilation openings on the power tool at regu-
lar intervals using non-metal tools. The blower of the
motor draws dust into the housing. An excessive accu-
mulation of metallic dust can cause an electrical hazard.
Before putting into operation, check the mains connec-
tion and the mains plug for damage.
Recommendation: The tool should always be supplied
with power via a residual current device (RCD) with a
rated current of 30 mA or less.