6. MALFUNCTIONS
ATTENTION: All checks shall be carried out by taking the appropriate security measures:
•
Do not check the connection of cables with the power switched on.
•
All cable connections and disconnections must be made with the power switched off.
•
Check that no one is in the door opening.
EN
Breakdowns that you can fix yourself:
Faults
The door does not
open / close
The door does not
open remotely
The motor works,
but the door doesn't
move
The motor is not
working
Motor breakdowns
Breakdowns that you cannot fix yourself:
Please have the following information available before contacting technical service:
•
The serial number (s/n), as shown on the rating plate.
•
The control panel has an error log, if possible provide the service centre with the error information.
Note: This error code can also be found in the control box manual.
38
This user manual must be handed to the customer and must be kept in a safe place throughout the whole period of use!
Possible cause
You have not connec-
ted the power supply
Error
• Obstacle
• Dirt in the guide
Defect in the remote
control
The door leaf is
separated from the
motor (unblock)
• The thermal protection
has reacted.
• Fuse.
• Control current circuit
interrupted.
Solution
Connect the power supply
Consult control panel error log. See if it is possible to
solve it, if not, contact the technical service.
• Remove the obstacle
• Clean the guide / photocells / light curtain
Change the batteries
Secure the door to the motor
• Let the motor cool down.
• Check the fuse status.
• Check the current.
See motor manufacturer's user instructions