AXIS T99A10 Positioning Unit 24 V AC/DC
1
I/O connector
2
Power connector
3
O-ring
NO
NO
NO TICE
TICE
TICE
Make sure the protective earth wire is about 10 mm (3/8 in) longer than the other two
wires (in the power cable), so that it will not be disconnected accidentally if pulled.
Note
We recommend that you strip approximately 90 mm (3½ in) of the power cable jacket and
70 mm (2¾ in) of the I/O cable jacket for ease of installation.
11. Install the power and I/O connectors, see Connectors on page 35.
12. Adjust the network, I/O and power cables so that the distance from the cable gasket to
the end of the connector is 240 mm (10 in), 170 mm (7 in), and 160 mm (7 in) respectively.
NO
NO TICE
NO
TICE
TICE
Make sure that the O-ring is fitted correctly around the transparent base unit cover.
All manuals and user guides at all-guides.com
22