4. ELECTRICAL CONNECTIONS

The single-phase motor includes a thermal protector. For three-phase motors, protection must be
provided by the user or installer.
- The plug on the pump cable must match the socket. Never modify the plug in any way. Do not
use any adapter plugs. Unmodifi ed plugs and matching plugs will reduce the risk of electric
shock.
- Avoid body contact with earthed surfaces.
- Do not abuse the cord. Never use the cord to carry, pull or unplug the pump. Keep cord away
from heat, oil, sharp edges, or moving parts. Damaged or entangled cords increase the risk of
electric shock.
- When operating a pump outdoors, use an extension cord suitable for outdoor use. Use of a cord
suitable for outdoor use reduces the risk of electric shock.
- The pump is equipped with a compatible plug. The power supply in your country must comply
with international regulations.
- If the power cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualifi ed persons in order to avoid hazards.
WARNING: Improper extension cords can be dangerous. If an extension cord is used, it must be
suitable for outdoor use and the connection must be kept dry and off the ground. It is recommen-
ded that this is done using a cable reel that keeps the plug at least 60 mm above the ground.
5. MAINTENANCE
Our pumps do not require specifi c maintenance, but the following operations are recommended:
- In case of temporary installation, the pump should be cleaned with clean water after use.
- In case of permanent installation, it is necessary to check every 3 months that the starting
mechanism is working properly (fl oat switch or sensor).
- Periodically remove any dirt that may accumulate in the crankcase.
- Do not expose to frost.
- Avoid dry running.
- Do not mistreat the cable. Never use the cable to carry, pull or unplug the pump.
- Clean the pump regularly if the suctioned liquid produces sediments.
- Avoid knocks, do not drop the pump.