SCS Sentinel prim' OneGate 3 Manual Del Usuario página 33

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Over current
7
setting
Open partially
8
(pedestrian
opening)
9
Pre-Flashing
Over current
A
reverse setting
Full open remote
switch
C
(on the remote
control)
Pedestrian open
remote switch
E
(on the remote
control)
7-0
4A
7-1
6A (fault)
7-2
8A
7-3
10A
7-4
12A
7-5
14A
7-6
16A
7-7
18A
7-8
20A
7-9
22A
8-1
10%
8-2
20%
8-3
30%
8-4
40%
8-5
50%
8-6
60%
The flashing light
9-0
blinks when the
gate starts to move
The flashing light
blinks 3 seconds
9-1
before the gate
starts to move
A-0
Stop
A-1
Reverse 1 second
A-2
Reverse 3 seconds
A-3
Reverse to the end
C-1
the top left button
C-2
the top right button
the bottom left
C-3
button
the bottom right
C-4
button
No function in
E-0
transmitter
E-1
the top left button
E-2
the top right button
the bottom left
E-3
button
the bottom right
E-3
button
The function can adjust the running
force of motor to be compatible with
the gate weight.
The factory setting is « 7-1 »
This function can adjust the time of
opening partially.
The factory setting is « 8-2 »
The factory setting is « 9-0 »
The factory setting is « A-3 » .
The reverse function only operates 3
times and then stops.
If gate reverses, the auto close
function will be cancelled.
The factory setting is « C-1 » .
The factory setting is « E-2 »
EN
33

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mco0062

Tabla de contenido