1
Retrofitting the bending box
Scope of delivery
1x "bending box" component
1x left-hand pedestal
1x installation manual (multi-language)
Mounting kit required
Included in the scope of supply of the 87.0-165 TL3 in-
verter
Technical data
General data
Protection class/overvoltage category
Max. conductor cross-section
Min. cable cross-section
Fitting for DC connection
Cable diameter for cable fitting
Torque for cable fitting
Interface screw connections
Cable diameter for cable fitting
Torque for cable fitting
Housing material
H x W x D
Weight
Remove the pedestal and DC input plate on the inverter
↻ The inverter is securely installed.
1 Unfasten the left-hand pedestal from the housing base of the inverter and place
in inverter packaging. [
2 Unfasten the input plate from the housing base of the inverter and make avail-
able for component. [
3 Set the screws for fastening the components to one side.
» The inverter is ready for component assembly.
Installing the component
↻ Left-hand pedestal and input plate removed.
1 Unfasten the housing cover of the inverter using the 6 screws and remove care-
fully [
T_25]
2 Lift the component by the DC input opening of the inverter and mount it provi-
sionally from below using the 4 screws that have been set to one side.
3 Tighten the fastening screws in a diagonally opposite sequence. [
5 Nm ]
» The component is securely installed. Proceed with the DC connection.
Bending-box S; XL Version
T_30].
T_30].
1x
Fig. 1: Mounting kit required
IP66 / NEMA 4X
240mm² (4x AL or CU)
in accordance with local installation stand-
ards
M40 (4x)
16 - 28 mm
10 Nm
PID (2xM16) max. 1.5mm
6 mm² (without wire sleeves)
4 (M25) 1.5 (M16) Nm
Aluminium
346x230x177 mm
1.6 kg
Fig. 2: Removing the pedestal and
DC input plate
1
2, 4 Fastening screws
3
T_30 /
Fig. 3: Mounting the component
on the inverter
1
2
3
2x
4x
2x
2x
2x
4
3
1
2
Input plate
Pedestal
1
2
3
Housing cover on inverter
Component
Fastening screws
Page 3