Working Instructions - Scheppach CGP1200 Traducción Del Manual De Instrucciones Original

Sistema de tratamiento de techo/pared/suelo universal 3 en 1
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 78
• Place the desired insert tool on the grinding spindle
(12).
• Screw on the clamping nut (14) and tighten it with the
two-hole assembly key (15).
NOTE Make sure that the collar of the clamping nut (14)
points outwards.
11.3 Fitting the dust extraction unit
Dusts from materials such as paint containing lead,
some types of wood, minerals and metal can be harm-
ful to health. Touching or inhaling the dust can cause
allergic reactions and/or respiratory diseases in the
user or persons in the vicinity.
Certain dusts such as oak or beech dust are consid-
ered carcinogenic, especially in combination with
additives for wood treatment (chromate, wood pre-
servatives). Material containing asbestos may only be
processed by specialists.
• Always use a dust extraction unit.
• Operate the electric tool either with the dust bag (18)
or a vacuum cleaner of dust class M.
• Make sure that the work area is well-ventilated.
• It is recommended to wear respirators with filter
class P2.
• Avoid kinking the suction hose (19).
Observe the regulations applicable in your country for
the materials to be machined.
• Connect the inlet side of the suction hose (19) onto
the suction port (8).
• Now connect the outlet side of the suction hose (19)
to the dust bag (18). Connect the outlet side of the
suction hose (19) into the suction port of the dust bag
(18) until the two push buttons of the suction hose
(19) engage.
• To disassemble the suction hose (19), first press the
push buttons on the sides of the suction hose (19).
Pull the suction hose (19) off the suction port (8).
11.4 Fitting the adapter for third-party extraction
• If necessary, connect the dust extraction adapter to
the suction port.
• Connect an approved dust extraction unit.
NOTE: When working with wood or materials that gen-
erate dust that is hazardous to health, the device must
be connected to a suitable, tested extraction device.
11.5 Adjusting the additional grip
The inclination of the additional grip (9) can be adjust-
ed. This is used to achieve a more favourable working
posture of the guide hand during certain applications
(e.g. when grinding close to the edge).
• Loosen the two wing screws and tilt the additional
grip to the desired working position.
• Retighten the wing screws.

12. Working instructions

m Attention!
Always make sure the device is fully assembled
before commissioning!
m WARNING!
Unplug the mains plug from the socket before car-
rying out any work on the device!
Wait until the device has come to a standstill be-
fore setting it down.
The removal rate and the surface quality are essential-
ly determined by the choice of grinding tool, the prese-
lected speed level and the contact pressure.
Only perfect grinding tools provide good grinding per-
formance and protect the device.
12.1 Grinding
• Hold the device firmly with both hands and en-
sure firm footing. It is safer to guide the device with
two hands.
• Connect your extraction system (own or third-party
extraction).
• With third-party extraction: If possible, work with
the remote switch-off or automatic start/stop func-
tion of the vacuum cleaner. The vacuum cleaner
switches on automatically and switches off again
with a time delay to remove residual dust from the
vacuum hose.
• Switch the device on. Place it with the entire grinding
surface on the surface to be machined. Move it over
the workpiece with moderate pressure.
• Ensure even contact pressure to increase the ser-
vice life of the insert tools.
• Excessively increasing the contact pressure does
not lead to a higher removal rate, but to greater wear
of the device and the insert tool.
• Lift the device from the surface.
www.scheppach.com
GB | 31

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

5903818901

Tabla de contenido