10. Cleaning and maintenance

Always pull out the mains power plug before starting
any cleaning work.
Cleaning
• Keep all safety devices, air vents and the motor
housing free of dirt and dust as far as possible.
Wipe the equipment with a clean cloth or blow it
with compressed air at low pressure.
• We recommend that you clean the device immedi-
ately each time you have finished using it.
• Clean the equipment regularly with a moist cloth
and some soft soap. Do not use cleaning agents
or solvents; these could attack the plastic parts of
the equipment. Ensure that no water can seep into
the device. The ingress of water into an electric tool
increases the risk of an electric shock.
Maintenance
There are no parts inside the equipment which re-
quire additional maintenance.
Service information
Please note that the following parts of this product
are subject to normal or natural wear and that the fol-
lowing parts are therefore also required for use as
consumables.
Wear parts*: grinding medium, Carbon brushes,
sharpening wheel, angle gauge, v-belt
* Not necessarily included in the scope of delivery!

11. Electrical connection

The installed electric motor is factory connected
ready for operation. The connection meets the
applicable VDE and DlN regulations. The con-
nection made by the customer as well as any ex-
tension cables used must comply with all rele-
vant regulations. Connection and repair work on
the elctric equipment must be carried out by a
qualified technician only.
Important note
The motor rating is S 1. This means that when over-
loaded it switches off automatically. After a cooling
period (can vary) you may switch it on again.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been im-
properly fastened or routed.
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H05VV-F".
The printing of the type designation on the connec-
tion cable is mandatory.
AC motor
• The mains voltage must be 230 V~
• Extension cable s up to 25 m long must have a
cross-section of 1.5 mm
.
2
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Motor data - type plate

12. Storage

Store the equipment and accessories out of children's
reach in a dark and dry place at above freezing tem-
perature. The ideal storage temperature is between 5
and 30 °C. Store the electric tool in its original pack-
aging.

13. Disposal and recycling

The equipment is supplied in packaging to prevent
it from being damaged in transit. The raw materials
in this packaging can be reused or recycled. The
equipment and its accessories are made of various
types of material, such as metal and plastic. Never
place defective equipment in your household refuse
The equipment should be taken to a suitable collec-
tion center for proper disposal. If you do not know the
whereabouts of such a collection point, you should
ask in your local council offices.