4.3.3 Alarm Setup
Alarms are inputs into the dome which require the dome to undertake a specific action. They may
come from a number of external sources, such as door entry systems or PIR motion sensors. The
Dennard 2060 dome has a clock function that enables the supervisor to select different actions
depending on the time of day or the day of the week. This clock function is not available in the
Dennard 2040, go to section 4.3.3.1. The Alarm Setup screen provides access to three options:
Alarm Action Setup
Mask Alarm
Select Holidays
Return
Exit
4.3.3.1 Alarm Action Setup
On selecting this function the supervisor must select an alarm number in the usual way with the
following screen:
Alarm Number___
0 1 2 3 4 5 6 7 8 9 0
Accept Entry
Clear Entry
Return Without Change
Delete Alarm
Accepting the Alarm number brings up the following screen:
Alm _ _ _ Select P or T
PTnnn
Old _ _ _ _
New _ _ _ _
0 1 2 3 4 5 6 7 8 9
Accept Entry
Clear Entry
Return Without Change
This allows a specified preset position P or tour T to be stored, along with its identification number
'nnn' which will be implemented when the alarm is activated. To select an option, use the code '01'
for Tour or '10' for Preset (the 1 under the P or T selects its use; 11 is invalid). Accepting the entry
will increment the alarm number allowing all inputs to have an action allocated to them or their
existing action, shown as 'Old', modified. The alarm action will be sustained for a duration set by
the user timeout (see section 4.3.4.1).
Dennard 2040 / 2060 Menu System Manual
All manuals and user guides at all-guides.com
(This screen is not applicable to Dennard 2040)
Page. 17