First insert the Ex-battery module Ex-AM PMR 1000 included in the scope of supply into the guide rails of the MasterEx Ex-PMR 1000.
Slide the battery module on the guides until the battery locking mechanism locks in position on the radio unit.
1. To switch on, turn the ON/OFF or volume control clockwise until a signal tone sounds.
2. To control the volume, turn the ON/OFF or volume control while simultaneously holding down the monitor key.
3. To select a channel, turn the channel switch to select the respective channel.
4. To transmit, press and hold PTT and speak into the microphone in a normal voice. Hold the microphone about 5 cm from your
mouth.
5. Release PTT to receive.
Please observe: If the battery voltage is too low, the transmission process will stop and the red LED display will flash. Further
information can be found at: "8.2 Functions - Low Battery Warning".
8.4.3.1 Channels
You can change the frequency allocation of the 16 pre-programmed channel storage spaces. Select a value from 0 – 8 to change the
frequency allocation of the selected channel.
Please observe: After programming is complete, switch the unit off and back on again, so that it is back in the operating mode.
If "0" is selected, the programmed channel is empty (no frequency).
1. Turn the radio unit on while pressing PTT and the monitor key. Only release PTT and the monitor key when the LED display
illuminates in orange.
2. Press PTT until the LED display changes from orange to green and a signal tone sounds, which means that the radio unit is in the
frequency setting mode.
3. Select the desired channel using the channel switch.
4. Using PTT, select the frequency number from the 9 different numbers 0-8. Each time you press it, the frequency number changes
accompanied by a signal tone.
Operation
Press and hold
PTT for 2 seconds
Press PTT one time
Press PTT two times
Press PTT three times
Press PTT four times
Press PTT five times
Press PTT six times
Press PTT seven times
Press PTT eight times
Please observe:
Select channel number "0" when not selecting any channel. To do so, press PTT for about 2 seconds until a 1-second long signal tone
sounds.
If PTT is pressed more often than 8 times, a signal tone sounds and no value is selected.
5. The respective signal tone of the selected number sounds after 2 seconds.
6. Press the monitor key to end this setting. The red LED flashes two times.
7. Press the monitor key again to confirm the signal tone of the desired number.
8. Program another channel as described in steps 3 through 7 above.
Example: Changing a channel storage space (11) to channel number 8
1. Select channel storage space 11 in the set mode.
2. Press PTT 8 times to select 8 as the channel number. Each time you press it, a signal tone will sound.
3. After 2 seconds, one long and three short signal tones sound, to confirm your selection of channel number 8.
4. Press the monitor key to complete the setting. The red LED display flashes two times.
5. Press the monitor key again. One long and three short signal tones confirm that channel number 8 has been selected.
-22-
All manuals and user guides at all-guides.com
8.4 Getting started
8.4.1 Inserting the battery module
8.4.2 Basic functions
8.4.3 Changing the pre-programmed storage spaces
Channel number
0
1
2
3
4
5
6
7
8
Signal tone
1 tono de un segundo
.
..
...
....
.....
-.
-..
-...