High quality lithium-ion batteries are used in your MasterEx Ex-PMR 1000. These batteries have numerous advantages in everyday
use, such as a low weight and high capacity in a nevertheless compact construction. In addition these batteries also exhibit practically no
memory effect.
However, these batteries are susceptible to a natural ageing process which impairs their functionality. Modern batteries today have a
lifespan of around 500 charge cycles, which, when used daily, corresponds to a service life of approximately 2 years. The ageing process
increases rapidly after this period, which means that the batteries are deemed technically defective after 500 charge cycles. Moreover, the
batteries could blow up and cause irreparable damage to your device in a worst case scenario.
For this reason rechargeable batteries with lithium cells should be replaced after 2 years at the latest or after reaching a battery capacity
that is 50% of its initial value.
Note: The battery used in this unit poses a fire hazard and can cause chemical injuries if it is used improperly. Neither the battery nor
the battery cells should be opened or disassembled and they should not be burned or exposed to temperatures exceeding 100°C.
No registration – no fees. Your radio unit is approved for short-range radio in many European countries without requiring registration or fees.
The handheld radio telephones (radio units) in a frequency range of 446.00625 – 446.09375 MHz are intended for the transmission of
speech. Only handheld radio units with integrated antennas may be used.
Please also observe the respective directives and telecommunications laws which are in effect for your specific country.
Repair work is subject to the nationally valid regulations and directives. We therefore recommend that such work be performed by the
manufacturer, as all repairs must be examined to ensure functional safety.
Old electrical equipment and "historic" old electrical equipment from the company will be disposal obligation and disposed of at no
cost in accordance with the EC Directive 2002/96/EC and the German Electrical and Electronic Equipment law of 16/03/2005. The costs
of the transport of the equipment to the company are borne by the sender.
In accordance with Article 1, Section 18 and Article 2 of the Act revising the law of Waste-Related Product Responsibility for Batteries
and Accumulators (Gesetz zur Neuregelung der abfallrechtlichen Produktverantwortung für Batterien und Akkumulatoren) dated 25 June
2009, we are obligated to provide the following information.
Your device contains a rechargeable lithium battery.
Depleted batteries or rechargeable batteries that can no longer be recharged should never be disposed of along with normal or
household waste. Old batteries can contain harmful substances that are hazardous to health and damaging to the environment. Please
return the batteries/rechargeable batteries. Return is free of charge and required by law. Please only dispose of discharged batteries in the
designated containers and tape the terminals of lithium batteries.
Note: The battery used in this unit poses a fire hazard and can cause chemical injuries if it is used improperly. Neither the battery nor
the battery cells should be opened or disassembled and they should not be burned or exposed to temperatures exceeding 100 °C.
If the battery needs to be disposed of, it can be removed as described under point (8.4.1). The disposal regulations specified above are
also applicable for old devices.
All batteries and rechargeable batteries can be recycled. Precious raw materials such as iron, zinc and nickel can therefore be reused.
The symbol
has the following meaning: Batteries and rechargeable batteries should not be disposed of along with normal or
household waste.
- Only use a suitable cloth or sponge to clean the unit. Do not use solvents or abrasive cleaning agents to clean the unit.
- We recommended having the function and the accuracy of the unit checked by the manufacturer every two years.
- The storage temperature should be within the permitted ranged of -20 °C to +45 °C.
- When the unit is not in use, the accessory sockets should be covered with the protective cap.
Under the general terms and conditions of business, the manufacturer offers a 2-year warranty for function and materials on this
product under the specified operating and maintenance conditions. Not covered are all wearing parts (e.g. batteries, sensors, displays,
lamps, etc.) as well as calibrations. We give a manufacturer's warranty of six months especially for the supplied Ex-batteries.
This warranty does not extend to products that have been used improperly, altered, neglected, damaged by accident or subjected to
abnormal operating conditions or improper handling.
In the event of a warranty claim, the faulty device should be sent in. We reserve the right to readjust, repair or replace the unit.
The above warranty terms represent the sole rights of the purchaser to compensation and apply exclusively and in place of all other
contractual or statutory warranty obligations. The manufacturer does not accept liability for specific, direct, indirect, incidental or
consequential damages or losses, including the loss of data, regardless of whether they are caused by breach of warranty, lawful or
unlawful actions, actions in good faith or other actions.
If in certain countries the restriction of statutory warranty and the exclusion or restriction of incidental or consequential damages
is unlawful, then it may be possible that the above restrictions and exclusions do not apply for all purchasers. If any clause in these
warranty terms should be found to be invalid or unenforceable by a competent court, then such a judgement shall not affect the validity
or enforceability of any other clause contained in these warranty terms.
-26-
All manuals and user guides at all-guides.com
10. Legal Information
11. Repairs
12. Disposal
13. Cleaning, maintenance and storage
14. Warranty and liability