Jandy TruDose Manual De Instalación Y Funcionamiento página 14

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Page 14
ENGLISH
Suction
Line
3.5"
(9 cm)
Weighted
Suction
Line
Strainer
Figure 12. Install Suction Weight to Suction Line
3.6.5
Discharge Line to Pump Head and
Injection Point
1.
Make a secure fi nger tight connection on the
discharge fi tting of the pump head as instructed in
the Install Suction Line Instruction section.
NOTE:
DO NOT use thread sealant tape on
pump tube connections or tools to tighten
connections.
WARNING
HAZARDOUS PRESSURE: Shut off water or
circulation and bleed system pressure.
NOTE:
Locate a point of injection beyond all pumps
and filters or as determined by the application.
2.
A 1/4" or 1/2" female NPT (FNPT) connection is
required for installing the injection fi tting. If there
is no FNPT fi tting available, provide one by either
tapping the pipe or installing an FNPT pipe tee
fi tting.
3.
Wrap the male NPT (MNPT) end of the injection
fi tting with 2 or 3 turns of threading tape. If
necessary, trim the injection fi tting quill as required
to inject product directly into the fl ow of water.
4.
Hand tighten the injection fi tting into the FNPT
fi tting.
5.
Install connecting nut and ferrule to the pump
discharge tubing. Insert discharge tubing into
injection fi tting until it reaches the base of the
fi tting.
6.
Finger tighten the connecting nut to the fi tting.
7.
Turn the pump on and re-pressurize the system.
Observe the fl ow as actuated by the system and
check all connections for leaks.
8.
After a suitable amount of dosing time, perform
test for desired readings. If necessary, fi ne tune the
dosing levels.
Jandy
NOTE:
3"
Typical Point of Injection
Figure 13. Install Discharge Line to Pump Head and
NOTE:
TruDose
Chemical Controller
®
TM
The injection point and fitting require periodic
maintenance to clean any deposits or buildup.
To allow quick access to the point of injection,
we recommend the installation of shut-off
valves.
Trim injection
fitting end
Check Valve
Injection Point
Using undiluted acid could lead to corrosion
or overfeeding issues. Use muriatic acid only
(not provided). Dilute the acid 4:1 following
the safety recommendations of the chemical
manufacturer, and use personal protective
equipment. For example: For a 5 gallon tank,
there would be 4 gallons of water and 1 gallon
of muriatic acid.
|
Installation & Operation Manual
DO NOT use teflon tape
on pump or tube threads
DO NOT use pliers
Injection Valve
Return Line

Publicidad

Tabla de contenido
loading

Tabla de contenido