REPlAcINg thE coolINg uNIt
12
Apply new thermal paste all the way around the pipe.
12
13
Fit the new cooling unit into the cabinet and tighten all the
screws at the back.
14
Seal around the frame of the cooling unit (with tape or
similar material) as damp protection.
15
Refit the heater, terminal box and the capillary tube in
exactly the same way they were found before.
16
Transfer the flue baffle from the old cooling unit.
17
Stand the refrigerator up and replace all screws inside the
freezer and vaccine compartment. Tighten the screws hard.
!
For proper function it is very important that
good contact between the cooling element and
the cooling unit itself is obtained.
18
Reattach the capillary tube end to the cooling element
inside the refrigerator.
19
Install the kerosene equipment.
20
Put the refrigerator on test.
oRdERINg SPARE PARtS
1
When ordering spare parts, always state:
•
Model (found on the data plate)
•
PRodUCT no xxx xx xx-xx (found on the data plate)
•
SeRIAl no xxx xxxxx (found on the data plate)
•
VolTAGe And WATTAGe (if electric parts are ordered)
•
SPARe PART deSCRIPTIon (see spare parts list)
•
SPARe PART no (see spare parts list)
2
The data plate is located on a wall inside the cabinet.
2
3
To order spare parts log on to
quotations for spare parts, fill out the form and then, click on send e-mail.
Appliances bearing this symbol must be deposited at the designated local reception point for the disposal of
electrical and electronic equipment. It is not permitted that this product be disposed of by way of the normal
household refuse collection system*.
www.sibir.com
www.sibir.com. Select contact and your country. Under select a topic, choose
12
2
MOD.NO.
V170KE
SIBIR
SIBIR
220 ~ Volt
1.4 Amp
INTERNATIONAL AB
TOTAL CAPACITY
BRUTTOINHALT
VOLUME BRUT
TESTED TO 60 bar
GEPRUFT AUF 60 bar
TYPE: RKE-2D
RATIFIÉ JUSQU'À 60 bar
Thermal paste
on pipe
PROD.NO.
921 17 50-05
SER.NO.
611 00001
300 Watt
CLIMATE CLASS
REFRIGERANT NH
3
170 L
KÄLTEMITTEL
NH
320 g
Na
CrO
=
3
2
4
AGENT FRIORIGÉNE NH
3
MADE IN SWEDEN
Typical data plate
*Only valid for EU countries.
copyright © sibir international
20
T
21 g