Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
Pressure points, where connection cables are
passed through windows or doors.
Kinks where the connection cable has been
improperly fastened or routed.
Places where the connection cables have been cut
due to being driven over.
Insulation damage due to being ripped out of the
wall outlet.
Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage. Check the electrical connection cables for
damage regularly. Ensure that the connection cables
are disconnected from electrical power when checking
for damage.
Electrical connection cables must comply with
the applicable VDE and DIN provisions. Only use
connection cables with the designation H05RR-F.
The printing of the type designation on the connection
cable is mandatory.
The mains voltage must be 230 V~
Extension cables up to 25 m long must have a
cross-section of 2.5 mm2.
Connections and repair work on the electrical
equipment may only be carried out by electricians.
Please provide the following information in the event
of any enquiries:
Data of machine type plate

11. Maintenance and cleaning

Danger!
Disconnect the mains plug before carrying out any
cleaning work.
Note: The welding machine must be serviced and
overhauled regularly to ensure proper operation and
compliance with safety requirements. Improper and
incorrect operation may result in failure and damage
to the device.
• Before carrying out any cleaning work on the
welding device, pull the mains cable 8 out of the
socket so that the device is safely disconnected from
the power supply circuit.
• Clean the outside of the welding device and its
accessories regularly. Remove dirt and dust using
air, a cleaning rag or a brush.
Note: The following maintenance work shall be carried
out only by qualified specialists.
• Current regulator, earthing device, internal wiring,
the welding torch coupling device and adjustment
screws should be serviced regularly. Retighten loose
screws and replace rusty screws (replacement M4 x
10 screws are available at any commercial hardware
store).
• Regularly check the insulation resistances of the
welding device. Use the appropriate measuring
device for this purpose.
• In the event of a defect or if it is necessary to replace
parts of the device, please contact the appropriate
specialist personnel.
Service information
With this product, it is necessary to note that the
following parts are subject to natural or usage-related
wear, or that the following parts are required as
consumables.
Wearing parts*: Earth clamp;
* may not be included in the scope of supply!

12. Transport

For easy transport of the welding machine, carry it
over the shoulder using the carrying strap provided or
simply carry by the transport handle.

13. Storage

Store the device and its accessories in a dark, dry and
frost-free place that is inaccessible to children. The
optimum storage temperature lies between 5 and 30
˚C. Store the power tool in its original packaging.
Cover the electric tool to protect it from dust or moisture.
Store the operating manual with the power tool.