Safety messages
MAIN CORDSET SELECTION
(THE FOLLOWING NOTE ONLY APPLIES ONLY TO THE UNITS
RATED 230V 50Hz, AND LOCATED IN THE EUROPEAN UNION)
CAUTION: WHEN CHOOSING A DETACHABLE LINE CORD
FOR USE WITH YOUR MFPP-C1, ALWAYS FOLLOW THE
FOLLOWING PRECAUTIONS
The cordset consists of three parts: the attachment plug, the cord and
the appliance inlet. Each of these components must have European
regulatory safety approvals.
The following minimum electrical ratings for the specific cordset are
published for safety purposes.
DO NOT USE CORDSETS THAT DO NOT MEET THE FOLLOWING
MINIMUM ELECTRICAL REQUIREMENTS.
PLUG: 3 amperes, 250 volts, 50/60 Hz, Class 1, 3 conductor, European
safety approved.
CORD: Type H05VV-F3G0.75, Harmonized (< HAR >). The "< >" symbols
indicate cord approved according to appropriate European standard
(NOTE: "HAR" may be substituted for approval mark of European safety
agency that approved the cord. An example would be "< VDE >").
APPLIANCE CONNECTOR: 3 amperes, 250 volts, 50/60 Hz, European
safety approved, Type IEC 320. The cordset shall not exceed 3 meters
in length. A cordset with component electrical ratings greater than the
minimum specified electrical ratings may be substituted.
FCC NOTE
(THE FOLLOWING NOTE ONLY APPLIES TO THE UNITS RATED
115V 60Hz.)
This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment.
This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the Operation Manual,
may cause harmful interference with radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at
his/her own expense.
CAN ICES-3 (A)/NMB-3(A)
CAUTION: ANY MODIFICATIONS MADE TO THIS DEVICE
THAT ARE NOT APPROVED BY GBC MAY VOID THE
AUTHORITY GRANTED TO THE USER BY THE FCC AND/
OR INDUSTRY CANADA TO OPERATE THIS EQUIPMENT.
Service, MFPP-C1
Do not attempt to service your MFPP-C1 yourself. Contact an authorized
service representative for any required repairs or major maintenance for
your MFPP-C1.
DO NOT REMOVE THE MACHINE'S COVER.
There are NO user-serviceable parts inside the machine in order to avoid
potential personal injury and/or damage to property or the machine itself.
Service, Diesets
Every dieset is thoroughly oiled at the factory prior to shipping. During
normal use this oil will be exhausted and should be replaced. As part of
regular maintenance, each dieset should be oiled.
See Section 8 MFPP-C1 Dieset Manual for instructions on servicing the
Diesets.
2. INTRODUCTION
Thank you for purchasing the MFPP-C1. It is a versatile production
system that will enable you to punch, crease & perforate documents for
a variety of binding styles by means of a simple die change. It has also
been designed for easy operation.
The MFPP-C1 is an innovative solution for punching, creasing &
perforating paper and offers the following design features:
Quick-change die sets that can be interchanged without any tools.
♦
♦
All MFPP-C1 die sets include an Identification Label providing the
user with the hole pattern and name.
♦
Convenient storage area for two extra Die Sets.
Duty Cycle and Product Positioning
The GBC MFPP-C1 provides a flexible, cost effective punching solution
for light to medium level punching production environments. It is
designed for production print users that typically punch their documents
at an average of 20-30% of their overall workflow. For customers that
run continuous punching for long runs of over 4 hours, performance may
vary or degrade due to a wide range of media weights and environmental
conditions that can occur.
AMPV - Nominal 600,000 average monthly print volume (A4/letter),
assuming volume is split 50/50 between punch and bypass (300,000
punch and 300,000 bypass).
Maximum Recommended Monthly Volume - The maximum
recommended monthly punch volume should NOT exceed 400,000.
Maximum Punch Duty Cycle - In addition to the aforementioned
conditions, no more than 2 sheets of 300gsm per 5 sheets of 75gsm
should be punched. The heaviest paper stocks are typically used as only
the front and back covers of the bound book application.
Operating Die Set Supplies
Dies are considered consumables and when worn, must be replaced.
Each die set has a 90-day warranty from the date of purchase. The
warranty is void if the die is used beyond its specifications.
Punch die life will be maximized if oiled every 250,000 punch cycles (see
Dieset Service for details)
Standard die sets have an expected life of 750,000 punches using 20 lb/
75 gsm paper, heavy duty (HD) die sets have an expected life of 4,000,000
cycles. This is a minimum life expectation only. Die life is NOT guaranteed
due to a wide range of media weights and environmental conditions that
the dies may endure. If you are going to be punching extended runs that
exceed the die use life, it is strongly recommended that you have extra die
sets on hand to continue with minimal downtime.
MFPP-C1
GB
4