Troubleshooting

Camera
Fault
ON/OFF Button was pressed, but camera
does not start up (no start up screen or
thermal image appears).
ON/OFF Button was pressed and green LED
comes on for 5 seconds, but no start-up
screen or thermal image appears.
Thermal image is out of focus, shows
permanent lines, or is unstable.
Battery capacity is not sufficient.
All manuals and user guides at all-guides.com
Cause
No battery or fully discharged battery
inserted.
Battery is over-discharged and the safety
circuit tripped.
LCD screen is damaged.
Sensor system or optical system is defective. Return camera to Dräger Safety for service.
Battery is only partially charged (not all bars
of the battery display are shown).
Battery is fully charged, but battery manager
does not show the real capacity of the pack.
Battery has aged to the point where the
capacity is not sufficient anymore.
Synchronizing the battery does not help.
Remedy
Insert a fully charged battery.
Battery needs to be re-charged while
disconnected from the camera. Take battery
out of the camera and charge with a desktop
charger or use battery-only charging slot in
the truck charger. If charging does not work,
contact Dräger Safety.
Return camera to Dräger Safety for service.
Insert a fully charged battery.
Synchronize battery: Fully charge the battery.
Switch on the thermal imaging camera and
allow it to run without interruption at room
temperature until it automatically shuts down.
Fully charge the battery again.
Replace battery.