Troubleshooting - Dräger UCF 6000 Instrucciones De Uso

Ocultar thumbs Ver también para UCF 6000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 76
4

Troubleshooting

Malfunction
Possible cause
Camera cannot be
The battery is empty. Recharge the battery.
switched on.
The battery screws
are loose.
Laser pointer is weak
Water droplets or dirt
or diffused.
is on the laser
emission window.
Dräger UCF 6000, UCF 7000, UCF 8000, UCF 9000
Malfunction
The charging cradle
Remedy
LEDs indicate an
error during the
charging process.
Tighten screws.
Clean the laser
emission window.
Troubleshooting
Possible cause
Remedy
The contacts on the
Clean contacts with a
battery and/or the
lint-free cloth.
charging cradle are
dirty.
The battery is too cold
Leave the battery in
or too hot.
the charger and place
charger in an area
with an ambient
temperature between
10 and 35 °C (50 °F
and 95 °F). The
charger will charge
the battery once the
temperature inside
the charger is correct.
It may take
significantly more
than an hour before
the internal
temperature reaches
the permissible range
again and charging
resumes since the
temperature is
measured directly on
the Li-ion cells.
47