Troubleshooting
If your Mission
does not work correctly, follow the trouble shooting guide below. If the fault persists, contact
TM
your dealer.
Symptom
The LED light on the
charging station does
not turn on.
Red light turns on the
charging station.
Your Mission
is
TM
inside its working
area but the display
says "outside
working area" and
the LED is green.
Mission
cannot
TM
correctly dock with
the Charging station.
Mission
runs
TM
14
outside the boundary
EN
wire. Mission
does
TM
not mow an area
within a boundary
wire zone. Mission
reverses or rotates
erratically near the
boundary wire.
Mission
exits the
TM
boundary wire due
to high speed when
going down a hill.
The position of
Mission
cannot
TM
be shown precisely
on the App, or its
position cannot be
detected.
Cause
There is no power.
The boundary wire isn't connected.
The boundary wire ends are
clamped incorrectly.
Environmental influences.
Poor connection caused by debris
on the charging strip.
The boundary wire of another
Mission
or another branded robotic
TM
mower is positioned too closely.
The boundary wire has been
installed with acute angles.
In wet conditions, the boundary wire
electric signal may leak where wire
TM
has been joined or repaired.
There is boundary wire electric signal
leakage due to broken insulation.
The cutting area is larger than the
allowable cutting area for Mission
The boundary wire is placed on a
slope steeper than 17% (10°).
The GPS signal is affected by the
weather or some interference.
You are not using the latest version
of the Mission
App.
TM
Check the charging station is connected
properly to the charger and the charger is
connected to a suitable power supply.
Check that the boundary wire has been
connected correctly to the charging station.
Check there are no breaks in the boundary
wire, especially in the wire ends.
Reverse the boundary wire ends.
Restart Mission
.
TM
Clean the contact pins located on the
charging station and the charging strip on
Mission
using a cloth.
TM
Ensure your Mission
least 1m of spacing between the neighboring
boundary wire.
Check the boundary wire to ensure the
angles are smooth.
Check boundary wire joints. Insulate to
provide a fully waterproof connection.
Repair damaged boundary wire insulation
with insulation tape.
Decrease the cutting area.
.
TM
Reposition the boundary wire away from
slopes that are steeper than 17% (10°).
1.Check and make sure: Mission
upside down or on its side; Mission
covered by some metal objects.
2. Take Mission
TM
can obtain a mobile signal.
Please update the Mission
latest version.
Solution
boundary wire has at
TM
is not
TM
is not
TM
to an open area where it
App to the