Optimus DC-800ETH Manual De Instrucciones página 23

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

COMPONENT
TYPE OF ALARM
GENERATING
ETH A
LINK FAIL
ETH B
LINK FAIL
NETWORK
ERROR
ROUTING
ERROR
MAIN POWER
POWER FAIL
AUX. POWER
POWER FAIL
"UNIT NAME"
CAPSULE ERROR
Acoustic alarm indicator (buzzer): The paging desk incorporates a buzzer that generates an acoustic signal when the paging
desk receives an alarm. The acoustic indication is a buzzing sound that lasts 10 seconds and is periodically repeated every 20
seconds.
This acoustic indication may be activated or deactivated through the configuration software.
If the acoustic indication is activated, it sounds each time an alarm is received.
The alarms may be silenced. To accomplish this:
Select the alarms tab ( ) using the  or  keys.
1.
Use the / navigation keys to select one of the alarms and press OK.
2.
Using the / keys, select the MUTE BUZZER option.
3.
4.
Press OK.
DC-800ETH version 4.3.001
DC-800ETH
DESCRIPTION
The connection to the unit's ETH A port
fails.
The connection to the unit's ETH B port
fails.
The unit does not respond to a network
ping.
Audio matrixes units that allow routing
communications in the system do not
operate properly.
Indicates a failure of the primary power
to the DC-800ETH.
Indicates a failure of the secondary power
to the DC-800ETH.
Indicates
a
capsule
error
microphone desk that is sending the
alarm.
RECOVERY
If the installation does not have a
redundant network, use the PA Manager
software to disable the displaying of the
Ethernet
Links
configurations to the unit.
If the installation has a redundant
network, check the cable connection to
the ETH A port on the unit.
If the installation does not have a
redundant network, use the PA Manager
software to disable the displaying of the
Ethernet
Links
configurations to the unit.
If the installation has a redundant
network, check the cable connection to
the ETH B port on the unit.
Check the unit's connection to the
Ethernet network. If the connection is
correct, check the network.
Check the primary power by ensuring the
paging desk is receiving 24 VDC through
the POWER SUPPLY terminal strip (see
figure 2, number 3).
If the installation does not have a
redundant power supply, use the PA
Manager
software
displaying of the Power supply alarm and
send configurations to the unit.
If secondary power is available, check
that the paging desk is receiving 24 VDC
through the power jack connector (see
figure 2, number 2).
of
the
R + D Department
IP Microphone desk
and Control central
alarm
and
send
alarm
and
send
to
disable
the
23

Publicidad

Tabla de contenido
loading

Tabla de contenido