3. Click on Network.
4. Modify
the
network
parameters as desired (IP,
Netmask and Gateway)
and click on the Change
Network Settings button
to apply the changes.
The
equipment
reboot automatically.

7. SYSTEM ALARMS

The unit incorporates several alarm systems that indicate that a fault has occurred in a component of the PA system.
GENERAL FAULT indicator light: Front yellow LED. Illuminates when the unit receives one or several alarms from the system or
when an alarm is generated by the unit itself.
SYSTEM FAULT indicator light: Front yellow LED. Illuminates when the equipment detects an internal error.
Acoustic alarm indicator (buzzer): Intermittent buzzing sound. The IF-702ETH incorporates a buzzer that generates an acoustic
signal each time an alarm is received. The acoustic indication is a buzzing sound that lasts 10 seconds and is periodically
repeated every 20 seconds. The buzzer may be deactivated through the Call Point software.
It is possible to disable the buzzer for the SYSTEM FAULT alarm (internal device error). To do this, remove the front cover and
remove the jumper JP1.
IF-702ETH version 5.0.001
IF-702ETH
will
JP1
R+D Department
IP Audio interface
2 outputs
15