26 / EN
Before connecting the heater, you must:
•
Check that the product characteristics comply with the requirements for its
correct operation. See table.
¡ELECTRICAL SPECIFICATIONS TABLE:
Model
Type
Power (W)
Supply voltage (VCA)
Phase
Amperage (A)
Recommended breaker (A)
Required cable diameter
•
The cable must be 100% copper.
•
Turn on your heater and check that it is working properly.
•
Replace the heater cap with the included screws (See Figure 3).
This heater must be installed according to the following indications regarding the
presence of:
•
Humidity: do not install the appliance in humid environments.
•
Ice: do not install the appliance in environments with a probability of temperatures
dropping to critical levels with a risk of ice formation.
•
Sun rays: do not expose the appliance directly to solar rays, not even through
glass.
•
Dust/vapors/gases: do not install the appliance in notably aggressive
environments, such as those with acid vapors, dusts, or saturated gas.
•
Electric discharges: do not install the appliance directly on electrical lines that are
not protected from voltage fluctuations.
Eleva 4 kW V2
Electric Instantaneous Water Heater
4000
127
1
31
40
10 AWG
Eleva 9,5 kW V2
9500
220
2
43
50
6 AWG
Eleva 12 kW V2
12000
220
2
55
60
4 AWG