Restoring the configuration
To restore the Touch module configuration:
1.
select it
2.
right-click on the description (a pop-up with 5 sub-menus will appear)
3.
select "Restore configuration"
4.
Select the file "UT9270 - Touch screen module ULTRA--.tar.gz" to load
We recommend using a micro-USB or Ethernet connection to reset the device configuration
The configuration can be reset using the file saved previously by ViP Manager (see section "Saving the
configuration") or using the micro-SD card on board art. UT9270.
The on-board micro-SD card saves all the settings and logs for the Touch module art. UT9270 and updates
them once a day.
To use the same settings on a new Touch module, proceed as follows:
1.
Remove the micro-SD card from the old unit
2.
Insert it into the PC using the special adapter provided
3.
Connect the new Touch module to the PC and establish a connection using the ViP Manager software
4.
Carry out the "Resetting configuration" procedure by selecting the file on the micro-SD card
5.
Send it to the new Touch module using the relevant software function
6.
Remove the micro-SD card from the computer
We recommend using a micro-USB or Ethernet connection to reset the device configuration