CHARACTERISTICS
• Hot water temperature: from 50°C to 85°C max.
• Cold water temperature: from 5°C to 15°C.
• Supply with cold water and hot water up to 70°C maximum (we recommend 50°C in public buildings
and 55°C in healthcare facilities to comply with UK Legionella control guidelines).
• Hot Water supply temperature: 55 - 85°C (the temperature differential between the hot water
and the cold water must be at least 50°C).
• Pressure: 1 – 5 bar (100 - 500 kPa), we recommend 3 bar (300 kPa).
• Maximum pressure differential at the inlets: 1 bar.
Safety:
- If the cold or hot water fails, the mixed water will shut off within 2 seconds.
- For anti-scalding failsafe, the hot and mixed water temperature differential must be at least 15°C.
- Check the anti-scalding failsafe at least twice a year and as often as necessary depending on the water
quality. Shut-off the cold water and check that the hot water stops within 2 seconds.
• This product is designed to withstand thermal and chemical shocks according to current guidelines.
NB: The anti-scalding failsafe is active if the cold water supply fails.
If, instead of cold water, hot water returns through a mechanical mixer, there is no anti-scalding safety.
We recommend installing a non-return valve on the cold supply to the mechanical mixer.
ADJUSTING THE FLOW RATE
• Flow rate regulated at 9 lpm ±1L at 3 bar for the mixer only or 6 lpm with shower heads ref.s 712 or 709.
NB: shower heads type 709 or 712 are supplied separately.
• To remove the cartridge from the body: remove the cover plate and the control lever as per Fig. P, Q,
R, W, X; shut off the water supplies and unscrew the extension (Fig. O) (NB. clockwise) and unscrew
the cartridge (Fig. N).
MAXIMUM TEMPERATURE LIMITER
The maximum temperature limiter is set using an adjuster screw. To adjust the temperature:
• Remove the control lever by unscrewing the grub screw (without fully removing it) using a 2.5mm Allen
key (Fig. W & X).
• Adjust the temperature by turning the screw (Fig. S) clockwise to decrease the temperature
and anti-clockwise to increase it.
• Replace the control lever (Fig. W & X).
Warning: No not remove the coloured collar.
INSTALLATION
• THE INTEGRITY OF THE SEALS BETWEEN THE STAINLESS STEEL WALL PLATE AND THE WALL
OR THE WALL PLATE AND THE MIXER AT LEAST ONCE A YEAR, AND MAKE GOOD IF NECESSARY.
If this advice is not followed, water may leak into the wall.
DELABIE cannot be held responsible for any ingress.
FOR FURTHER INFORMATION PLEASE CALL DELABIE TECHNICAL SUPPORT UK: 01491 821821.
ALL OTHER MARKETS: +33 (0)3 22 60 22 74.