Exposed Shower Kit
• Position the shower kit so that the shower head is 2.10m high in relation to the floor.
• Recessed supply: use DELABIE elbow connectors ref. 836020 or 838020 for installations
with 150mm centres.
• Exposed supply: use the DELABIE reinforced wall plate ref. 824800 with four fixing points
for a secure assembly.
Shower Panel Model
• Drill a Ø 56 (ref. 790970) diameter hole in the panel.
• Unscrew the wall plate.
• Mount the mixer on the panel and replace the wall plate.
• Tighten the three screws using a 3mm Allen key.
REMEMBER
• Our mixers must be installed by professional installers in accordance with current regulations
and recommendations in your country, and the specifications of the fluid engineer.
• Sizing the pipes correctly will avoid problems of pressure loss and unwanted noise. .
• Protect the installation with filters, water hammer absorbers and pressure reducers to reduce
the frequency of maintenance. (Recommended pressure: 1 - 5 bar).
• Install stopcocks close to the mixer to facilitate maintenance.
• The pipework, stopcocks, mixers and all sanitary ware must be checked regularly, and at least once a year.

ADJUSTING THE FLOW RATE

The flow rate is pre-set at the factory at 3 lpm (at 3 bar) for washbasins and 12 lpm (at 3 bar) for showers.
For washbasins the flow rate can be adjusted directly on the adjustable flow straightener using a 2.5mm
Allen key:
- Notch n°1 = 3 lpm (at 3 bar).
- Notch n°2 = 4 lpm (at 3 bar).
- Notch n°3 = 5 lpm (at 3 bar).
If the adjustable flow straightener on a washbasin tap is replaced by an aerator, or a standard
flow straightener is fitted to a shower, the flow rate can be adjusted without shutting-off the water
supply or removing the mechanism (fig. E):
- Unscrew the central cap h using a pair of circlip pliers.
- Insert a 3mm Allen key in the centre of the push-button. Open the valve and turn the Allen key to
the achieve the desired flow rate.
- Replace the central cap h.
Shower kits fitted with the TONIC-JET, ROUND or GYM shower head do not require adjustment,
the flow rate is restricted to 6 lpm by the integrated flow regulator.
MAXIMUM TEMPERATURE LIMITER
The maximum temperature limiter is pre-set at the factory. To override it:
- Unscrew the central cap h and screw i and remove the push-button control j to gain access
to the index ring k (fig. F) with the temperature limiter m (fig. G).
- The water temperature at the mixer outlet is governed by the position of the index ring: remove the index
ring and replace it and check the maximum temperature at the TEMPOMIX outlet (fig. G).
WARNING: Do not remove the index ring k (fig. F).
If a thermostatic mixing valve is installed upstream, adjust the maximum temperature limiter with
the TEMPOMIX in the full hot water position.