The unit works
Check the air filter for
with reduced
dirt.
capacity
Check if the air duct is
blocked.
Check if the doors or
windows are open.
Check if the desired
operation is selected
and the temperature is
properly set.
The exhaust hose is
detached
Water leakage Overflow while moving
the unit.
Check if the drain
hose is kinked or bent.
Excessive
Check if the unit is
noise
securely positioned.
Noise sounds like
water flowing.
Check for loose
vibrating external
parts.
Error Codes
E0
Communication fault
between main PCB
and display PCB
Clean the air filter if
necessary.
Clear the obstacle.
Keep doors and windows
closed.
Select the desired
operation.
Make sure that the exhaust
hose is properly attached.
THE PRODUCT OR EQUIPMENT CONTAINS
FLUORINATED GREENHOUSE GAS.
Empty the water before
Art.nr.
transporting.
Straighten the hose.
Coolant:
Quantity in kg:
Place the unit on a flat,
Global Warming Potential:
level, horizontal surface.
CO2 Equivalent in tons:
Noise comes from flowing
refrigerant. This is normal.
Secure and tighten loose
ENVIRONMENT
external parts.
the end of its durability, but must be offered at a central point for the
Check the wire harness of
recycling of electric and electronic domestic appliances. This symbol
the PCB for damage.
on the appliance, instruction manual and packaging puts your
attention to this important issue. The materials used in this appliance
E1
Ambient temperature
sensor failure.
E2
Coil temperature
sensor failure.
Ft
Condensate water
high level alarm.
AC-5552
R290
0.24
3
0.00072
This appliance should not be put into the domestic garbage at
Instruction manual
Check connection. Clean or
replace the temperature
EN
sensor.
Check connection. Clean or
replace the temperature
sensor.
Remove the rubber plug
and drain the unit,
13