Advanced Options; Manual Control - Motion CM-35 Manual

Ocultar thumbs Ver también para CM-35:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

M O TI O N CM - 3 5 E LE CT RON IC C UR TA IN M O T O R
11
Reset the blind
It is possible to only delete end limits or to do a factory reset.
Factory reset will delete the end limits and remove the connection to any paired remote.
20
Press the program button on the motor to activate program mode.
11.1
Delete end limits: To delete the end limits of the blind hold the program button
until the blind stops stepping for the first time, keep holding the button until the
blind stops stepping for the second time. (approximately 10 seconds)
Factory reset: To reset the blind to factory defaults hold the button for at least 20 seconds.The blind will
stop stepping twice. After the second stop the blind will give one extra step to confirm factory reset.
M O T I O N C M -3 5 E L EC TR ONI C C U R TA I N MOT OR

Advanced options

12

Manual control

In case there is no remote control or pull control, the blind can
be operated with the program button on the motor.
Hold the program button to manually operate
12.1
the blind.The blind will move as long as the
button is being pressed. (max. 15 sec.)
To move the blind in opposite direction, release
12.2
the program button and repeat step 12.1.
13
Single select 5 channel remote
Single select makes it possible to activate program mode on a single blind through a
remote control, without having to physically press the program button on the blind.
To activate
13.1
Single select
+
simultaneously
hold the center
button and press
the pair button.
Once a blind is found the
To search for
13.3
13.4
channel LED will flash
the next blind
press the right
and the blind starts
stepping, indicating that
button. Search
program mode has been
mode will be
activated. The blind
activated.
can now be (un)paired
To find the
to the remote and/or
previous blind
programmed.
press the left
button.
The remote starts searching
13.2
for blinds (search mode).
This is indicated by the LED's
flashing from left to right.
To exit
13.5
Single select
press the
right button
during
search
mode.
21