Connecting Diagram - Motion CM-35 Manual

Ocultar thumbs Ver también para CM-35:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

M O TI O N CM - 3 5 E LE CT RON IC C UR TA IN M O T O R
2

Connecting diagram

IMPORTANT:
When the mains cable is permanently connected, a readily accessible disconnect
device must be incorporated externally to the motor.
When there is a pluggable connecter installed on the mains cable, the socket-
outlet must be installed near the motor and shall be
easily accessible.
14
Program
button
Mains Cable 230V
120V
Neutral
Blue
White
Phase
Brown
Black
Ground
Yellow-green
Green
M O T I O N C M -3 5 E L EC TR ONI C C U R TA I N MOT OR
3
Pair a remote
Pair a remote control that is able to program blinds. See pages 6 and 7
for remote controls details. In this manual CM-12 is displayed.
Shortly press the program button on the
3.1
motor. The blind will start stepping, indicating
that program mode has been activated.
(The blind remains stepping until the program
mode is de-activated.)
Select a desired channel for the blind using the
3.2
channel selection button on the remote control.
Press the pair button on the back of the remote
3.3
control to pair the blind to the selected channel.
The blind will shortly stop stepping indicating
that the remote has been paired to the blind.
Repeat steps 3.1 - 3.3 to remove a blind from
a channel.
End limits must be programmed to use a blind properly and to prevent it from being damaged.
Proceed to step 7 if end limits are already set.
4
Check direction of rotation
WARNING:
risk of damage.
Stop the blind before reaching
the end positions.
Channel
indicator
Channel
Pair
Selection
button
Shortly press the down button to check if the
4.1
blind moves the right way: away from the
Up
motor. If the blind moves the other way, the
rotational direction must be changed.
Down
Simultaneously press the up and down button
4.2
to change the direction of rotation.
15

Publicidad

Tabla de contenido
loading

Tabla de contenido