KCB 240-ST
Battery Crimping Tool
to the normal.
Micro computer control system with the feature of self-pressure detecting,
double protection during operation, counting and realize the exchange
between computer with data by the converter.
Table 1.
Series
Error code
No
On ---
1
E01
2
●●●
3
●—5sec
4
E02
5
●●●●
E03
6
●●●●●
E04
7
Instruction
What it means
Self-checking to assure
Self-checking
everything is ok
Hydraulic system may
Overload
damaged and need
check immediately
Charging
Lacking power and need
signal
charging.
Power lacking
No power and need
warning
charging immediately
Temperature sensor and
Sensor error
power inspecting error
Temperature
Temperature too high,
warning
tool need to be cold
Motor working but
No pressure
without pressure
OPERATING INSTRUCTION
Read the entire SAFETY INFORMATION section at the beginning of this manual
including all text under subheadings therein before using this product.
Use this tool for the manufacture's intended purpose only. Use other than that which is
described in this manual can result injury or property damage.
1. Charging
Push battery into charger and connect the plug with the plug seat. Make sure the room
temperature is between 10℃-40℃。The charging time is around 2 hours. Please see the
illustration below.
www.grupotemper.com