REPAIR PARTS LIST
Repair parts are determined by toilet tank number which can be found marked inside tank.
NOTE: "XXX" represents color or trim finish options. Specify when ordering.
PART NO.
DESCRIPTION
738938-XXX0A
TRIP LEVER - STANDARD LEFT HAND
034783-XXX0A
BOLT CAP KIT
7381125-400.0070A
FLUIDMASTER 400A VALVE
7381146-401.0070A
FLUSHVALVE ASSEMBLY 3 INCH (INCLUDES FLAPPER)
7381193-201.0070A
FLAPPER ASSEMBLY 3 INCH
7301021-0070A
TANK COUPLING KIT #253
738570-100.0070A
REFILL TUBE
735127-400.XXX
TANK COVER
735124-400.XXX
TANK COVER
7381146-405.0070A
FLUSHVALVE ASSEMBLY HET - 3 INCH (INCLUDES FLAPPER)
7381146-406.0070A
FLUSHVALVE ASSEMBLY HET - 3 INCH (INCLUDES FLAPPER)
7381146-402.0070A
FLUSHVALVE ASSEMBLY 3 INCH (INCLUDES FLAPPER)
7381148-200.0070A
EZ INSTALL BOLT CAP KIT
7381162-200.0070A
EZ INSTALL TANK COUPLING KIT
7381193-203.0070A
FLAPPER ASSEMBLY 3 INCH
PROBLEM
POSSIBLE CAUSE
Does not flush
a. Water supply valve closed.
b. Supply line blocked.
c. Flush valve chain too loose or disconnected.
d. Sand or debris lodged in water control.
Poor or sluggish flush
a. Bowl water level too low.
b. Supply valve partly closed.
c. Partially clogged trapway and/or drain pipe and/or vent.
d. Supply pressure too low.
Toilet leaks
a. Poor supply line connection.
b. Poor bowl to tank/floor connection.
Toilet does not shut off
a. Flush valve chain too tight, holding flush valve open.
b. Flush valve seat and/or flapper worn or deformed.
c. Sand or debris lodged in water control.
In the United States:
American Standard Brands
P.O. Box 6820
Piscataway, New Jersey 08855
Attention: Director of Consumer Affairs
For residents of the United States, warranty
information may also be obtained by calling
the following toll free number: (800) 442-1902
www.americanstandard-us.com
TROUBLESHOOTING GUIDE
a. Open valve and allow water to fill tank.
b. Shut off water supply, disconnect supply line and inspect all gaskets and
c. Readjust chain length as required.
d. Shut off water supply. Remove cap and clean as per Step 13.
a. Check that refill tube is connected to water control and inserted into tank
b. Open supply valve fully. Be sure that proper supply tube size is used.
c. Remove obstruction. Consult a plumber if necessary.
d. Normal supply pressure must be at least 20 psi.
a. Review Step 9 of installation procedure.
b. Review Step 4 through 7 of installation procedure.
a. Readjust chain length as needed. Review Step 10.
b. Shut off water supply. Replace flush valve.
c. Shut off water supply. Remove cap and clean per Step 13.
In Canada:
AS Canada ULC
5900 Avebury Rd.
Mississauga, Ontario
Canada L5R 3M3
Toll Free: (800) 387-0369
www.americanstandard.ca
- 4 -
TANK NUMBER
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
CORRECTIVE ACTION
washers. Reassemble. Also, see Fluidmaster maintenance. (see Step 13)
overflow without being kinked or damaged.
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
In Mexico:
Customer Service Manager
AS Maquila, S.A. de C.V.
Via Morelos #330
Col. Santa Clara
Ecatepec 55540 Edo. Mexico
www.americanstandard.com.mx
730110 2- 100 Rev. K
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔