Before Use; Language Settings - SANUSLIFE ECAIA ionizer S Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
3.5
Assembly of the alkaline outlet hose and the acidic water tap
3.6

Before use

The appliance requires a 230V (US model 120V) power supply.
The appliance switches on automatically when the water supply is opened.
Pressure adjustment: Adjust the water pressure so that the bars are in the „normal"
range.
Note: The ECAIA ionizer S is only suitable for cold drinking water!
3.7

Language settings

For language settings, refer to the complete instruction manual.
3.8
Control of the ionization performance
You can check the ionization performance by measuring the pH value. To do this, use the
indicator liquid supplied together with the pH scale (A-8).
For 5 to 10 milliliters of test water you need 1-2 drops of indicator liquid.
Ideally, the water should turn purple (pH 9 to 9.5) in the range of alkaline levels 3 or 4. If
this is not the case, you will fi nd further setting options in the complete instruction manual.
Screw the alkaline outlet hose (A-2) to
the upper water outlet (B-5).
Connect the plastic hose for acidic
water 7/9 mm (A-4) to the lower water
outlet (B-12) and the acidic water tap
(A-3).
8

Publicidad

Tabla de contenido
loading

Productos relacionados para SANUSLIFE ECAIA ionizer S

Este manual también es adecuado para:

Ecaia ionizer s+

Tabla de contenido