How To Stop; Before Starting; Before Each Start-Up; How To Start - Bostitch BTEC25200 Traducido De Las Instrucciones Originales

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

English
clockwise to increase pressure and counterclockwise to
decrease pressure.
Cooling system (not shown): This compressor contains
an advanced design cooling system. At the heart of this
cooling system is an engineered fan. It is perfectly normal
for this fan to blow air through the vent holes in large
amounts. You know that the cooling system is working
when air is being expelled.
Air Compressor Pump (not shown): Compresses air into
the air tank. Working air is not available until the compressor
has raised the air tank pressure above that required at the
air outlet.
Drain Valve: The drain valve 
the air tank and is used to drain condensation at the end of
each use.
Check Valve (not shown): When the air compressor is
operating, the check valve is "open", allowing compressed
air to enter the air tank. When the air compressor reaches
"cut-out" pressure, the check valve "closes", allowing air
pressure to remain inside the air tank.
Motor Overload Protector (not shown): The motor has
a thermal overload protector. If the motor overheats for
any reason, the overload protector will shut off the motor.
The motor must be allowed to cool down before restarting.
To restart:
1. Set the On/Off switch to "Off" and unplug unit.
2. Allow the motor to cool.
3. Plug the power cord into the correct branch
circuit receptacle.
4. Set the On/Off switch to "On" position.
Quick Connects : The quick connects 
quick connect plugs. The two quick connect bodies allow
the use of two tools at the same time.
How to Use Your Unit (Fig. A, B)

How to Stop

1. Set the On/Off switch 
 1 
2. Unplug unit when not in use.

Before Starting


WARNING: Do not operate this unit until
you read this instruction manual for safety,
operation and maintenance instructions.

Before Each Start-Up

1. Set the On/Off switch 
 1 
2. Plug the power cord into the correct branch circuit
receptacle. (Refer to Voltage and Circuit Protection
paragraph in the installation section of this manual.)
3. Turn regulator knob 
 4 
counterclockwise until fully
closed. Ensure regulated pressure gauge reads 0 psi.
6
7
is located at the base of
accepts industrial
5
to "Off".
to "Off".
Fig. B
4. Attach hose and accessories.
5. Ensure all covers and labels are in place, legible (for
labels) and securely mounted. Do not use compressor
until all items have been verified.

WARNING: Risk of unsafe operation. Firmly grasp
air hose in hand when installing or disconnecting
to prevent hose whip.

WARNING: Risk of unsafe operation. Do not use
damaged or worn accessories.
nOTE: This unit is equipped with quick connects
hose or accessory being connected will require a quick
connect plug.

WARNING: Risk of Bursting. Too much air pressure
causes a hazardous risk of bursting. Check the
manufacturer's maximum pressure rating for air
tools and accessories. The regulator outlet pressure
must never exceed the maximum pressure rating.
NOTICE: Risk of property damage. Compressed air
from the unit may contain wa ter condensation and
oil mist. Do not spray un fil tered air at an item that
could be damaged by moisture. Some air tools and
accessories may require filtered air. Read the
in struc tions for the air tools and accessories.

How to Start

1. Set the On/Off switch 
 1 
to build. Motor will stop when tank pressure reaches
"cut-out" pressure.
2. Turn regulator knob 
 4 
clockwise to increase pressure
and stop when desired pressure is reached.

WARNING: Risk of unsafe operation. If any
unusual noise or vibration is noticed, stop the
compressor immediately and have it checked by
a trained service technician.
The compressor is ready for use.
MAINTENANCE

WARNING: To reduce the risk of serious personal
injury, turn unit off and disconnect it from
power source before making any adjustments or
removing/installing attachments or accessories.
An accidental start-up can cause injury.

WARNING: Risk of unsafe operation. Unit
cycles automatically when power is on.
When performing maintenance, you may be
exposed to voltage sources, compressed air,
or moving parts. Personal injuries can occur.
4
5
. The
to "On" and allow tank pressure

Publicidad

Tabla de contenido
loading

Tabla de contenido