Always replace the lamp with a lamp of the same power and type: Xenon
1500W / XOP-15.
Procedure:
1) Unscrew the screws of the glass.
2) Remove the glass.
3) If the unit is new, carefully remove the protective foam that holds the lamp.
4) If you are replacing the lamp, carefully remove the existing lamp.
5) Insert the new lamp
6) Replace the glass and the 4 screws.
ATTENTION:
Do not plug in or turn on the stroboscope until the protective glass has been
replaced!
Troubleshooting
Here are some suggestions if you are having problems with your S-1500Pro-MKII.
The device does not work at all.
o Check the power cord and fuse.
o Make sure your outlet is well powered.
The fixture does not respond or does not respond correctly to DMX commands.
o Check your DMX cables
o Check your DMX addressing
o Try another DMX controller
o Make sure that your DMX cables do not run close to high-voltage cables,
which could cause interference.
Cleaning
The exterior of the unit should be cleaned regularly. The glass should be cleaned for
optimum brightness. If the unit is installed in a dusty or smoky environment this regular
maintenance is very important. It may be necessary to clean the glass from the inside as
8