Volt
40
Electric Fan Heater
Congratulations!
You have purchased the finest agricultural building heater available.
Your new L.B. White heater incorporates the benefits from the most experienced
manufacturer of heating products using state-of-the-art technology.
We, at L.B. White, thank you for your confidence in our products and welcome
any suggestions or comments you may have...contact us at 1-(800)-345-7200,
or email us at customerservice@lbwhite.com.
The herein installation instructions are the L.B. White Co. LLC
suggested recommendations and guidelines for temporary or
permanent installation of the L.B. White Co. LLC heaters. Local,
state, and electrical and safety code requirements supersede
these guidelines.
CE040
NOTICE
SCAN THIS
with your smartphone or
visit https://bit.ly/3qjEEkw to
view maintenance videos
for L.B.White heaters.
* Requires an app like QR Droid
for Android or for iPhone
40kW

Publicidad

Tabla de contenido
loading

Resumen de contenidos para L.B.White Volt 40

  • Página 1 SCAN THIS with your smartphone or visit https://bit.ly/3qjEEkw to view maintenance videos for L.B.White heaters. * Requires an app like QR Droid for Android or for iPhone WORLD PROVIDER - INNOVATIVE HEATING SOLUTIONS 411 Mason Street, Onalaska, WI 54650 • 800-345-7200 • 608-783-5691 • 608-783-6115 (fax) • www.lbwhite.com...
  • Página 2: Tabla De Contenido

    Volt™ 40 Electric Fan Heater TABLE OF CONTENTS Specifications .........................3 General Information ......................3 Operation Instructions ....................4 Maintenance Instructions ....................4 Storage Instructions ......................4 Wiring Diagram .......................4 Service Parts Identification .....................6 Warranty Policy.......................8 IMPORTANT INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING THIS HEATER ■...
  • Página 3: Specifications

    Volt™ 40 Electric Fan Heater Specifications Volt™ 40 Power (kW) Maximum Output per Hour (BTU/H) 51,200 / 102,400 / 136,500 (2 Stage Selector) Airflow (CFM) 1,765 Electrical Connection (VAC/Hz/Phase) 480/60/3 Partial: 20 Partial: 40 Amperage Draw (A) Full: 50 Ambient Thermostat Temperature Range 32 - 100 °F (0 - 40 °C) Length (in.) 46.0...
  • Página 4: Operation Instructions

    Volt™ 40 Electric Fan Heater Operation Instructions REVIEW AND UNDERSTAND ALL WARNINGS IN 3. Set the room thermostat to a temperature above THIS MANUAL. THEY ARE ESSENTIAL FOR SAFE the ambient room temperature by turning the USE OF THE HEATER. knob.
  • Página 5: Wiring Diagram

    Volt™ 40 Electric Fan Heater Wiring Diagram Contactor Toggle switch for +8kW output C1/4 Pole 4 of contactor C1 (open) Ambient Thermostat C2/C3/C4 Contactor Cooldown thermostat Fuse TO 1 Overheat limit switch (inner) Fan motor TO 2 Overheat limit switch (discharge) R1...R15 Heating element Transformer 480V/24 V, AC...
  • Página 6: Service Parts Identification

    Volt™ 40 Electric Fan Heater Service Parts Identification Schematic - Volt™ 40 Chassis (See Fan Enclusure Schematic) Parts List - Volt™ 40 Chassis Item Description Part # Outer Cover (White) (Incl. Connection Hatch) 474372 Outer Cover (Green) (Incl. Connection Hatch) 474372G Handle 474371...
  • Página 7 Volt™ 40 Electric Fan Heater Service Parts Identification Schematic - Volt™ 40 Fan Enclosure Parts List - Volt™ 40 Fan Enclosure Item Description Part # Bushing, Large 474353 Contactor (4/Heater) 474340 Auxillary Contact 474338 Strain Reliever 474355 Toggle Switch 474343 Fuse Holder 474376 Fuse...
  • Página 8: Warranty Policy

    Warranty Policy HEATER (LIMITED WARRANTY) L.B. White electric fan heater products are professional The warranty set forth above is the exclusive warranty provided construction heaters. They are warranted for twelve (12) by L.B. White, and all other warranties, including any implied months from original date of purchase.
  • Página 9: Solo Para Uso Profesional

    ESCANEE ESTO con su teléfono inteligente o visite https://bit.ly/3qjEEkw para ver los vídeos de mantenimiento de los calefactores L.B.White. * Requiere una aplicación como QR Droid para Android o para iPhone PROVEEDOR MUNDIAL - SOLUCIONES INNOVADORAS DE CALEFACCIÓN 411 Mason Street, Onalaska, WI 54650 • 800-345-7200 • 608-783-5691 • 608-783-6115 (fax) • www.lbwhite.com...
  • Página 10: Instrucciones Importantes

    Volt™ 40 Ventilador calefactor eléctrico ÍNDICE DE CONTENIDOS Especificaciones ......................3 Información general ......................3 Instrucciones de uso .......................4 Instrucciones de mantenimiento ..................4 Instrucciones de almacenamiento ..................4 Diagrama de cableado ....................4 Identificación de las piezas de repuesto .................6 Política de garantía ......................8 INSTRUCCIONES IMPORTANTES LEA TODAS LAS INSTRUCCIONES ANTES DE UTILIZAR ESTE CALEFACTOR ■...
  • Página 11: Especificaciones

    Volt™ 40 Ventilador calefactor eléctrico Especificaciones Volt™ 40 Potencia (kW) Potencia máxima por hora en (BTU/H) 51,200/102,400/136,500 (Selector de 2 etapas) Caudal de aire (CFM) 1,765 Conexión eléctrica (VCA/Hz/fase) 480/60/3 Parcial: 20 Parcial: 40 Amperaje (A) Completo: 50 Rango de temperatura del termostato 32-100°...
  • Página 12: Instrucciones De Uso

    Volt™ 40 Ventilador calefactor eléctrico Instrucciones de uso REVISE Y ENTIENDA TODAS LAS ADVERTENCIAS calor”, es decir, si está ajustado para una EN ESTE MANUAL. SON ESENCIALES PARA EL temperatura superior a la temperatura actual USO SEGURO DEL CALEFACTOR. Seleccione el rango de potencia con los interruptores marcados como S1, S2 y S3.
  • Página 13: Diagrama De Cableado

    Volt™ 40 Ventilador calefactor eléctrico Diagrama de cableado Contactor Interruptor de palanca para C1/4 Polo 4 del contactor C1 (abierto) una potencia de +8 kW C2/C3/C4 Contactor Termostato de ambiente Fusible Termostato de enfriado Motor del ventilador TO 1 Interruptor de límite de R1...R15 Elemento calefactor sobrecalentamiento (interior)
  • Página 14: Esquema De Identificación De Piezas De Repuesto Volt™ 40 Chasis

    Volt™ 40 Ventilador calefactor eléctrico Esquema de identificación de piezas de repuesto Volt™ 40 Chasis (Consulte el esquema del recinto del ventilador) Lista de piezas - Volt™ 40 Chasis Artículo Descripción N.° de pieza Cubierta exterior (blanca) (Incl. Compuerta de conexión) 474372 Cubierta exterior (verde) (Incl.
  • Página 15: Esquema De Identificación De Piezas De Repuesto - Volt™ 40 Reciento De Ventilador

    Volt™ 40 Ventilador calefactor eléctrico Esquema de identificación de piezas de repuesto - Volt™ 40 Reciento de ventilador Lista de piezas - Volt™ 40 Recinto de ventilador Artículo Descripción N.° de pieza Buje, grande 474353 Contactor (4/calefactor) 474340 Contacto auxiliar 474338 Aliviador de tensión 474355...
  • Página 16: Política De Garantía

    Política de garantía La garantía expuesta anteriormente es la única garantía proporcionada CALEFACTOR (GARANTÍ LIMITADA) por L.B. White, y se rechaza expresamente cualquier otra garantía, Los productos de calefacción eléctrica con ventiladores lo que incluye cualquier garantía implícita de comerciabilidad o de L.B.

Este manual también es adecuado para:

Ce040

Tabla de contenido