Technical Data; Voltage Versions And Electrical Data - Miele PWM 912 EL/RH Plano De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 66

Voltage versions and electrical data

3N AC 400 V EL
Supply voltage
Frequency
Required fuse rating (on site)
Power rating
Connection cable, min. cross-section
3N AC 400 V RH
Supply voltage
Frequency
Required fuse rating (on site)
Power rating
Connection cable, min. cross-section
3 AC 230 V EL
Supply voltage
Frequency
Required fuse rating (on site)
Power rating
Connection cable, min. cross-section
3 AC 400 V EL
Supply voltage
Frequency
Required fuse rating (on site)
Power rating
Connection cable, min. cross-section
3 AC 440/480 V EL
Supply voltage
Frequency
Required fuse rating (on site)
Power rating
Connection cable, min. cross-section
en - Technical data
3N AC 400 V
3N AC 400 V
3 AC 230 V
3 AC 400 V
3 AC 440/480 V
8,8/10,4 kW
50/60 Hz
16 A
9,6 kW
2,5 mm²
50/60 Hz
16 A
9,6 kW
2,5 mm²
50/60 Hz
35 A
9,6 kW
4 mm²
50/60 Hz
16 A
9,6 kW
2,5 mm²
50/60 Hz
16 A
2,5 mm²
41

Publicidad

Tabla de contenido
loading