Service Information - Black and Decker CT6 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

16 • ENGLISH
The compressor must be disposed in conformity with
the methods provided for by local regulations.
Important! To assure product SAFETY and RELIABILITY,
repairs, maintenance and adjustment (other than those
listed in this manual) should be performed by authorized
service centers or other qualified service personnel,
always using identical replacement parts.
CLEANING
Warning! Blow dirt and dust out of the main housing
with dry air as often as dirt is seen collecting in and around
the air vents. Wear approved eye protection and approved
dust mask when performing this procedure.
ACCESSORIES
Recommended accessories for use with your tool are available at
extra cost from your local dealer or authorized service center.
Warning! The use of any accessory not recommended
for use with this tool could be hazardous.
PROTECTING THE ENVIRONMENT
Separate collection. This product must not be
disposed of with normal household waste.
Should you find one day that your BLACK+DECKER
product needs replacement, or if it is of no further
use to you, do not dispose of it with household waste.
Make this product available for separate collection.
PROBLEM
Leakage of air from the valve of the
pressure switch with the compressor off.
Reduction of performance. Frequent
start-up. Low pressure values.
The compressor stops and restarts
automatically after a few minutes.
After a few attempts to restart, the
compressor stops.
The compressor does not stop and the
safety valve is tripped.

SERVICE INFORMATION

BLACK+DECKER offers a full network of company-owned
and authorized service locations. All BLACK+DECKER
Service Centers are staffed with trained personnel to provide
customers with efficient and reliable power tool service. For
more information about our authorized service centers and if you
need technical advice, repair, or genuine factory replacement
parts, contact the BLACK+DECKER location nearest you.
SPECIFICATIONS
Power
Speed
Tank Size
Pressure
Air Flow
Cylinders
Lubricated
Weight
TROUBLESHOOTING
POSSIBLE CAUSE
Check valve that, due to wear or dirt on
the seal, does not perform its function
correctly.
Excessive performance request, check
for any leaks from the couplings and/or
pipes. Intake filter may be clogged.
Tripping of the thermal cutout due to
overheating of the motor.
Tripping of the thermal cutout due to
overheating of the motor (removal of
the plug with the compressor running,
low power voltage).
Irregular functioning of the compressor
or breakage of the pressure switch.
Separate collection of used products and packaging
allows materials to be recycled and used again.
Re-use of recycled materials helps prevent
environmental pollution and reduces the demand
for raw materials. Local regulations may provide for
separate collection of electrical products from the
household, at municipal waste sites or by the
retailer when you purchase a new product.
CT6
0,5HP (0,38kW)
4200/min (rpm)
6L (1,58 Gal)
8 Bar (116 PSI)
55 L/min (1,94 CFM)
1
No
6kg (13,2lb)
POSSIBLE SOLUTION
Unscrew the hexagonal head of the
check valve, clean the valve seat
and the special rubber disk (replace
if worn). Reassemble and tighten
carefully (Figs. 14).
Replace the seals of the fitting, clean
or replace the filter.
Clean the air ducts in the conveyor.
Ventilate the work area. Reset the
thermal cutout. On lubricated type
models, check oil level and quality.
Activate the on/off switch. Ventilate the
work area. Wait a few minutes. The
compressor will restart independently.
Remove any power cable extensions.
Remove the plug and contact
the Service Center.