In order to prevent damage the iDuctor and the coil must be allowed to
cool thoroughly after use before they are returned to their storage box.
Both the unit and the coils can become hot in use.

3.6 Error messages

The iDuctor has a number of (patented) internal safety features. If one of these trips
the unit will switch off and the LED will flash when the on/off button is depressed. The
iDuctor is equipped with a patented microprocessor induction generator. In the event
of overloading or overheating of the generator the processor automatically reduces the
power to prevent damage to the induction generator.
3�7 Overheating protection
The unit will stop heating whenever its internal temperature rises too high.
Check:
1) that the fan is still operating
2) that the ventilation holes are unblocked
3) that power is connected, to ensure cooling
4) that only coils approved by the manufacturer are being used.
Solution: Delay heating until the unit has cooled sufficiently. The unit monitors the
temperature itself, and it will not be usable until the internal temperature has fallen
sufficiently. This will be detectable as you will hear the fan switch off.
3�8 Connection safety feature
Check:
1) that the coil is correctly connected
2) that the coils are not damaged
3) that the coils are not causing a short-circuit to earth or between the coils
3�9 Mains current protection
Check:
If a generator is being used, check whether the iDuctor operates correctly
when connected to the mains. It is possible that the power, voltage or frequency
provided by the generator is not correct.
3�10 Voltage and current protection
Check:
1) that the mains voltage is not too high
2) that the coil is not causing a short-circuit to earth, or internally
3) where the flexible coil is being used, that not too many turns have been wound
around the object to be heated. Solution: Remove some turns from the object to be
heated and retry.
3�11 Maintenance
The iDuctor is maintenance-free. The housing can be cleaned with a dry cloth.
CAUTION!
Do not use a wet cloth or solvents: these can damage the unit or its
operation. Do not use an induction coil if the insulating protective sleeve
is damaged or worn.