Final Installation - Furrion CHILL ACR13SA Serie Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Furnace Cable
7.
Locate the 12 VDC power cable (red, tagged with "+12
VDC") and ground cable (black, tagged with "Ground (12
VDC)" ) of the control box. And connect them with the
corresponding 12 VDC wire prepared in the ceiling.
12VDC wire from the
ceiling
12VDC Power Cable
Ground cable
8. Install the control box onto the mounting frame and fix with
2 provided "short" screws (one each side).
9. Stick the freeze sensor into the center bottom of the
evaporator. Then insert the clamp into the evaporator
between the fins to fix the freezer sensor.
Clamp
Freezer
sensor
Freeze Sensor Cable
Rooftop Unit
Cable
Room Sensor Cable
Wire Connection - Multizone
1.
Determine zone identification for each ceiling controller,
and set DIP switches appropriately per the DIP switch
selection section.
2. Choose the appropriate zone to operate the furnace, for all
other ceiling controllers set the Furnace DIP switch to "off"
to prevent mis-communication.
3. Repeat the wiring steps covered in the single zone
controller for each independent wall controller.
115VAC Power Cord
115VAC Power
Cord
4. Combine all the "To wall thermostat" wires together so that
all zones are connected, and each wire function matches.
Only one connection point should be made directly to the
wall controller / thermostat. Ensure no wire function is
crossed throughout the connections.
Analog Connection
The analog connection is only intended for use with
OneControl® provided by Lippert Control Systems. It allows
connection directly to the HVAC control module without use of
a separate gateway box.
To connect appropriately:
1.
Activate the analog harness by turning the DIP switch on
as indicated in the DIP switch selection section. This will
deactivate the digital "wall thermostat" harness.
Analog Cable
2. Connect the harness function according to the
OneControl® instructions.
3. Connect freeze sensor.
Clamp
Freezer
sensor
Freeze Sensor Cable
Rooftop Unit
Cable
Room Sensor Cable

Final Installation

1.
Tuck/secure LED cable (white strip, tagged with "LED") out
of the way. This wire is reserved for lighting options.
LED Cable
2. Install the Air Distribution Box (ADB) shroud over the
mounting frame and fix with the 4 provided long screws, or
#8 x1.5" (max) pan head RV screws can also be used.
NOTE: Make sure the "THIS WAY FRONT" mark is facing
front (the direction of the vehicle) while installing.
- 10 -
115VAC Power
Cord
CCD-0005730 Rev: 04-25-22

Publicidad

Tabla de contenido
loading

Tabla de contenido