77885
GREEN TO GROUND
VERDE A TIERRA
VERT DE MISE À LA TERRE
6-32 x 1-1/8" SCREWS
TORNILLOS DE 6-32 x 1-1/8"
VIS 6-32 x 1-1/8"
Installation & Operating Instructions for the
Westinghouse Ceiling Fan/Light Wall Control
WARNING: SHUT POWER OFF AT
FUSE OR CIRCUIT BREAKER
SAFETY PRECAUTIONS:
WARNINGS:
• To avoid fire, shock, and serious personal injury, follow all instructions
carefully. Read and save these instructions for future reference.
• Do not install or use this unit if any part is damaged or missing.
• WARNING! To reduce the risk of fire or electric shock, do not use it with
any additional solid state fan speed control device, or any additional
variable speed control.
NOTICE:
1. This control is designed to operate only one ceiling fan and accessory light kit.
2. This wall control is rated for a maximum (ceiling fan only) of 1.0 motor amp at 120
volts, and total lamp wattage equaling 80 Watt maximum.
3. Make sure no bare wires are exposed outside of the connectors.
4. All wiring must conform to National and Local Electrical Codes. If you feel
that you do not have enough electrical wiring knowledge or experience, have
your fan control installed by a licensed electrician. Any electrical work not
described in this manual should be performed by a licensed electri-
cian.
5. Use of this control with some ceiling fans could result in fire, shock,
and serious personal injury. Use this fan control only with capacitor
speed controlled ceiling fans only.
MAKING THE ELECTRICAL CONNECTIONS:
NOTE: Installation of this control requires that the three-conductor cable with
ground wire be run between the control wall box and the ceiling fan outlet.
1. If your ceiling fan is equipped with variable speed and light ON/OFF pull
chain switch controls, make sure to set the speed control at the highest
speed and the light to the ON position before installing the wall control. This
will avoid erratic speeds and possible damage to your ceiling fan.
2. Verify proper operation of the ceiling fan wall control before installation.
Improper wiring can damage the control and will void the warranty.
3. Disconnect power to the ceiling fan at the main electric panel. Remove the
fuse or switch the circuit breaker to the OFF position.
4. Remove the wallplate to expose the wiring and disconnect the existing
switch. Install the control in a metal or plastic wall box.
5. Make electrical connections as follows:
• Connect the black wire marked with "TO MOTOR L" from the wall
control to the BLACK wire from the fan.
• Connect the BLUE wire from the wall control to the RED or BLUE wire
from the fan.
• Connect the black wire marked with "AC IN L" from the wall control to
the 120v AC HOT wire.
• Use the wire connectors provided to secure the connections.
• Connect the GREEN/Ground wire from wall control to the grounding
wire from wall box.
NOTE: Refer to the diagram on the back of the wall control.
1. Secure the wall control to the wall box using the two 6-32" x 1-1/8" screws provided.
2. Press the wallplate onto the wall control with an appropriate force.
3. Restore power at main electrical panel.
4. Operate ceiling fan and light by pressing the fan speed / light buttons to desired
speed / light level.
Westinghouse Lighting, Philadelphia, PA 19154-1029, U.S.A. www.westinghouselighting.com
and Westingouse are trademarks of Westinghouse Electric Corporation.
BLACK (AC IN L)
NEGRO (ENTRADA CA L)
NOIR (AC DANS L)
BLACK
NEGRO
NOIR
BLUE
AZUL
BLEU
BLACK
NEGRO
NOIR
BLUE (FOR LIGHT)
AZUL (PARA LA LUZ)
BLEU (POUR LAMPE)
BLACK (TO MOTOR L)
NEGRO (AL MOTOR L)
FAN
NOIR (à MOTEUR L)
VENTILADOR
VENTILATEUR
HOW TO OPERATE YOUR WALL CONTROL:
The remote buttons function as follows:
(1) Fan speed:
= High speed
= Medium-high speed
= Medium Speed
= Low Speed
(2)
Button: Turn the fan off
(3)
- Light On/Off - press and release light button.
- Light Dimmer - continuously press the light
button to brighten the light
- Light Dimmer - continuously press the light
button to dim the light.
Power off switch- Carefully take off the wallplate
and pull out this switch for cutting off the AC power.
Note: This switch to designed to disconnect the power if the
ceiling fan is not used for a long time.
SET button
(under the small wallplate):
The SET button is recessed into the hole,
use a hard, slender object, such as a needle,
to insert into the SET hole. It is for setting
suitable dimmer level.
1. When the light flickers after dimming,
you can use this button to improve this
as following:
Turn on the fan light and dim light to
a suitable level, then short-press the SET
button, the light will turn off and back on,
it means the new dimmer level is activated
and memorized.
2. Press and hold the SET button for 3
seconds to clear the memorized dimmer
level. The light will turn off and back on,
it returns to the default dimmer level.
WARNING! HOOK UP "IN SERIES" ONLY!
Do not connect to hot and neutral wire of electric circuit or switch will
be damaged. Refer to diagram above.
TROUBLESHOOTING GUIDE
PROBLEM: WALL CONTROL FAILS TO OPERATE
Check:
• Is there power to the control unit?
• Is the control unit wired correctly?
• Are the fan and light switches set on the highest position?
LIMITED WARRANTY
The Westinghouse universal ceiling fan/light wall control offers a limited war-
ranty of one year from the date of purchase to the original owner against defects
in material and workmanship. All spare parts are covered for ninety days only. This
warranty is in lieu of all other warranties expressed or implied.
Westinghouse will repair or replace this universal ceiling fan/light wall control if
it is defective due to faulty materials or workmanship. This warranty does not cover
service charges, defects resulting from accidents, damages caused through abuse
or alterations or by affixing any attachment not provided with the product, improper
installation or maintenance, failure of supporting devices not supplied as original
mounting hardware, exposures to extremes of heat or humidity, incorrect voltage,
surges in current, unauthorized repair, or failures caused by modifications of the
product or the acts of third parties. See remote manual for proper installation.
If this product fails for any reason covered by this warranty, please contact
us at www.westinghouselighting.com/contact-us.
Used under license by Westinghouse Lighting.
AC 120V
INPUT
BLACK
NEGRO
NOIR
BLUE
AZUL
BLEU
WHITE
BLANCO
BLANC
BLACK
NEGRO
GREEN TO GROUND
NOIR
VERDE A TIERRA
VERT DE MISE À LA TERRE
Wallplate
Small Wallplate
Power O Switch
All Rights Reserved.
Instrucciones de instalación y funcionamiento para
el control de pared para ventilador de techo/juego
de luz Westinghouse
¡ADVERTENCIA! DESCONECTE
EL SUMINISTRO ELÉCTRICO
QUITANDO EL FUSIBLE O
APAGANDO EL CORTACIRCUITO.
PRECAUCIONES DE SEGURIDAD:
ADVERTENCIAS:
• Para evitar incendios, descargas eléctricas y heridas personales graves,
siga todas las instrucciones con cuidado. Lea y guarde estas instruc-
ciones para referencia futura.
• No instale ni utilice esta unidad si alguna pieza está dañada o falta.
• ¡ADVERTENCIA! Para reducir el riesgo de incendio o descarga eléc-
trica, no lo use con cualquier dispositivo de control de velocidad de
ventilador de estado sólido adicional, o cualquier control de velocidad
variable.
AVISO:
1. Este control está diseñado para operar solo un ventilador de techo y un
juego de luces auxiliares.
2. Este control de pared está clasificado para un máximo (solo ventilador de
techo) de 1,0 amperios de motor a 120 voltios y un vataje total de la lámpara
de 80 vatios como máximo.
3. Asegúrese de que no queden cables desnudos fuera de los conectores.
4. Todo el cableado debe cumplir con los códigos eléctricos nacionales y
locales. Si tu sientes que no tiene suficiente conocimiento o experiencia en
cableado eléctrico, tenga su control de ventilador instalado por un electricista
calificado. Cualquier trabajo eléctrico no descrito en este manual
debe ser realizado por un electricista calificado.
5. El uso de este control con algunos ventiladores de techo podría provo-
car incendios, descargas eléctricas y heridas personales graves. Use
este control de ventilador solo con ventiladores de techo controlados
solo por capacitor de velocidad.
REALIZACIÓN DE LAS CONEXIONES
ELÉCTRICAS:
NOTA: La instalación de este control requiere que el cable de tres
conductores con cable a tierra entre la caja de pared de control y
la salida del ventilador de techo.
1. Si su ventilador de techo está equipado con tirador de cadenilla para
velocidad variable y controles de luz ENCENDIDO/APAGADO, asegúrese
de establecer el control de velocidad variable en la posición de velocidad
más alta y la luz en la posición ON (encendido) antes de instalar el control
de pared. Esto evitará velocidades erráticas y posibles daños a su ventila-
dor de techo.
2. erifique que el control de pared del ventilador de techo funcione correct-
amente antes de la instalación. El cableado inadecuado puede dañar el
control y anulará la garantía.
3. Desconecte la alimentación del ventilador de techo en el panel eléctrico
principal. Quitale el fusible o cambie el corta circuito (disyuntor) a la posición
APAGADO.
4. Retire la placa de pared para exponer el cableado y desconecte el exis-
tente. Instale el control en una caja electrica de metal o plástico.
5. Realice las conexiones eléctricas de la siguiente manera:
• Conecte el cable negro marcado con "TO MOTOR L" del control de
pared al cable NEGRO del ventilador.
• Conecte el cable AZUL del control de pared al cable ROJO o AZUL del ventilador.
• Conecte el cable negro marcado con "AC IN L" del control de pared
al el cable VIVO de CA de 120 V.
• Utilice los conectores de cables provistos para asegurar las conexiones.
• Conecte el cable verde del control de pared al cable de conexión
puesto a tierra de la caja de pared.
NOTA: Consulte el diagrama en la parte posterior del control de
pared.
1. segure el control de pared a la caja electrica usando los dos tornillos de
6-32" x 1-1/8" provistos.
2. Presione la placa de pared contra el control de pared con fuerza adecua-
da.
3. Restaure la energía en el panel eléctrico principal.
4. Opere el ventilador de techo y la luz presionando los botones de luz/velocidad del
ventilador al nivel deseado.
Made in China
77885