WARNINGS:
• To avoid fire, shock, and serious personal injury, follow all
instructions carefully. Read and save these instructions for
future reference.
• Do not install or use this unit if any part is damaged or miss-
ing.
• IMPORTANT! Fan installation must be complete, including the
assembly of blades, before testing the remote control unit.
NOTICE:
A. MAKING THE ELECTRICAL CONNECTIONS:
NOTE: This remote only works
with some fans that are installed
in sloped ceilings.
Do not use fan speed control in
canopies where the mounting is
not as described in figures 4 or 5.
This remote cannot be installed in a
downrod style fan when in flushmount
mode (when downrod is not in use).
1. Disconnect existing wiring between ceiling fan and AC sup-
ply at electrical junction box.
2. FOR FANS ON A DOWNROD: Remove ceiling fan canopy
from its mounting plate. (See figure 4.)
FOR FLUSHMOUNT FANS: Remove decorative housing
from mounting plate (see figure 2). Disconnect mounting
bracket from mounting plate and allow to hang from one side
(see figure 3).
3. Making the electrical connection:
• Connect GREEN fan wire to BARE (ground) wire.
• Connect BLACK control unit wire to BLACK supply wire
(AC L).
• Connect WHITE control unit wire to WHITE supply wire
(AC N).
• Connect WHITE control unit wire (MOTOR N) to WHITE
fan wire.
• Push the connected wires up into the junction box. Place
BLACK wires on one side of box, and WHITE, GREEN and
BARE (ground) wires on the other side of the box.
B. INSTRUCTIONS FOR YOUR NEW WESTINGHOUSE REMOTE FAN CONTROL SYSTEM
Please open the back cover
of the remote transmitter,
and find the blue toggle
switch. It is preset at "1" for
non-dimmable lamp. If
you're planning to
use Incandescent Lamp or
dimmable lamp,
Slide up the toggle switch at
"ON" to active light dimmer
function."
The remote buttons function as follows:
1. High speed – When you press the "Hi" key, it will emit 3 long beep sounds indicating the fan is starting up;
Med speed – When you press the "MED" key, it will emit 2 long beep sounds indicating the fan is starting up;
Low speed – When you press the "LO" key, it will emit 1 long beep sound indicating the fan is starting up;
Fan off – When you press the "OFF" key, it will emit 4 short beep sounds indicating the fan is turning off;
TROUBLESHOOTING GUIDE
PROBLEM: REMOTE FAILS TO OPERATE
Check:
• Is there power to the control unit?
• Is the control unit wired correctly?
• Are the fan and light switches set on the highest position?
• Is there a good battery in the remote?
• Are the switches set the same in both the remote and the control unit?
PROBLEM: SHORT RANGE
Solution:
• If the remote can operate the control unit when close to it but does not oper-
ate it at distances of 30-50 feet, try placing the black antenna wire above the
ceiling and outside of the junction box.
Westinghouse Lighting, Philadelphia, PA 19154-1029, U.S.A. www.westinghouselighting.com
, WESTINGHOUSE, and INNOVATION YOU CAN BE SURE OF are trademarks of Westinghouse Electric Corporation.
SAFETY PRECAUTIONS:
1. This remote control is rated for a maximum (ceiling fan only) motor amp
of 0.80 at 120 volts, total (lamp) wattage equaling 300 watt maximum.
2. Do not use with solid state ceiling fans.
3. The decorative housing (canopy) at the ceiling must be metal.
The metal housing acts as a protective cover for the Control Unit.
DO NOT USE WITH A NON-METALLIC HOUSING.
4. Only the remote unit should be used to change fan speeds. Do not use
the pull chain to change fan speeds after installation.
5. Make sure no bare wires are exposed outside of the connectors.
FIGURE 1
CONTROL
UNIT
WHITE
WHITE
AC SUPPLY
AC SUPPLY
BLACK
BLACK
AC SUPPLY
BARE (GROUND)
• Connect BLACK control unit wire (MOTOR L) to BLACK fan wire.
• Connect BLUE control unit wire (FOR LIGHT) to BLUE
light wire.
• Push the connected wires up into the junction box.
• Lay the BLACK control unit wire (ANTENNA) on top of the
control unit.
• FOR FANS ON A DOWNROD: Lay the control unit in the
canopy (see figure 4). Reinstall the canopy on its mount-
ing plate. Restore electrical power to the circuit.
• FOR FLUSHMOUNT FANS: Attach the control unit to
the mounting plate or to the ceiling with the supplied tie
wraps (see figure 5). Reconnect the mounting bracket to
the mounting plate (see figure 2). Reinstall the decorative
housing on its mounting plate. Restore electrical power to
the circuit.
NOTE: If the unit does not fit properly between the
mounting plate and ceiling, attach the unit to the
underside of the mounting plate.
WARNING: HIGH VOLTAGE
TRANSMITTER
(BACK OF REMOTE)
Before connecting this control unit:
• Disconnect electrical power from the circuit to be used.
• Household power can cause serious injury or death.
TOGGLE SWITCH
• Wiring must meet all local electrical code requirements.
Remote control setting and speed control setting process:
All remote controls will be preset up a pair of codes when being manufactured. After
installing the unit and restoring power to your fan, press and hold the "OFF" button for
5 seconds. You must press the "OFF" button within 60 seconds of restoring power to
the fan. The speed setting process is completed after hearing 4 short beep sounds.
FIGURE 6
LIMITED WARRANTY
The Westinghouse remote control for ceiling fans offers a limited war-
ranty of one year from the date of purchase to the original owner against
defects in material and workmanship. All spare parts are covered for
ninety days only. This warranty is in lieu of all other warranties expressed or
implied.
Westinghouse will repair or replace this remote control if it is defec-
tive due to faulty materials or workmanship. This warranty does not cover
service charges, batteries, defects resulting from accidents, damages caused
through abuse or alterations or by affixing any attachment not provided with
the product, improper installation or maintenance, failure of supporting
devices not supplied as original mounting hardware, exposures to extremes
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
FIGURE - 2
FLUSHMOUNT FANS ONLY
BLUE
BLUE
LIGHT
BLACK
BLACK
FAN
FAN
WHITE
WHITE
GREEN
FAN
FIGURE - 4
DOWNROD FANS ONLY
CONTROL
UNIT
2. Light On/Off – When you press the "LIGHT" key, it will emit only 1 short beep sound indicating when the
light is turned on or off.
3. Light Dimmer – When the toggle switch is set at "ON" position, continuous pressure on the light button
dims light in a continuous cycle from light to dark, or dark to light. It will emit 2 short beep sounds indicating
the dimming level.
Used under license by Westinghouse Lighting.
Installation & Operating Instructions for the
Westinghouse Ceiling Fan and Light Remote Control
6. All wiring must conform to national and local electrical codes. If you
feel that you do not have enough electrical wiring knowledge or experi-
ence, have your fan control installed by a licensed electrician. Any
electrical work not described in this manual should be performed
by a licensed electrician.
7. Do not use water or detergents to clean the remote transmitter unit. A
dry dust cloth will be suitable for most cleaning.
8. Use of this control with some ceiling fans could result in fire, shock,
and serious personal injury. Use this fan control with capacitor
speed controlled ceiling fans only.
FIGURE - 3
FLUSHMOUNT FANS ONLY
FIGURE - 5
FLUSHMOUNT FANS ONLY
JUNCTION BOX
CEILING
MOUNTING PLATE
FIGURE 7
of heat or humidity, incorrect voltage, surges in current, unauthorized repair,
or failures caused by modifications of the product or the acts of third parties.
See remote manual for proper installation.
If this product fails for any reason covered by this warranty,
please contact us at www.westinghouselighting.com/contact-us.
All rights reserved.
77871
CONTROL UNIT
Made in China

Publicidad

loading

Resumen de contenidos para Westinghouse 77871

  • Página 1 30-50 feet, try placing the black antenna wire above the ceiling and outside of the junction box. Westinghouse Lighting, Philadelphia, PA 19154-1029, U.S.A. www.westinghouselighting.com , WESTINGHOUSE, and INNOVATION YOU CAN BE SURE OF are trademarks of Westinghouse Electric Corporation. Used under license by Westinghouse Lighting. All rights reserved.
  • Página 2 Westinghouse Lighting, Philadelphia, PA 19154-1029, U.S.A. www.westinghouselighting.com , WESTINGHOUSE, and INNOVATION YOU CAN BE SURE OF are trademarks of Westinghouse Electric Corporation. Used under license by Westinghouse Lighting.
  • Página 3 à l’extérieur de la boîte de disjoncteurs. Westinghouse Lighting, Philadelphia, PA 19154-1029, U.S.A. www.westinghouselighting.com , WESTINGHOUSE, and INNOVATION YOU CAN BE SURE OF are trademarks of Westinghouse Electric Corporation. Used under license by Westinghouse Lighting.