American Standard 6245 Serie Manual Del Propietário página 7

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MAINTENANCE
1
ADJUST STOP VAVLE
IMPORTANT: TO AVOID OVERFLOWING, THE STOP VALVE (3) MUST NEVER BE OPENED TO THE
POINT WHERE THE FLOW FROM THE VALVE EXCEEDS THE FLOW CAPACITY OF THE FIXTURE.
1. After installation is complete, peel off the PROTECTIVE FILM (1) from the sensor. Standing to one side,
block the sensor with your hand for 10 seconds. Remove your hand and listen for audible "click" from
within the valve.
2. Remove STOP VALVE COVER (2) from STOP VALVE (3).Turn on water supply 1/4 turn to 1/2 turn(CCW)
and test for leaks.
Note: Unit may flush for approximately 5 to 10 sec. when water is first turned on. If flow persists,
turn water off and repeat step #1 above.
3. Actuate the FLUSH VALVE:
A) Cover sensor with hand for 10 seconds. NOTE: Stand outside of sensor detection area.
B) Remove hand from in front of the sensor; unit will flush in approximately 3 seconds.
4. Adjust STOP VALVE (3) after each flush until the stated flush volume is achieved, no splashing occurs and
the fixture is properly cleansed.
5. When adjustment is complete, replace STOP VALVE COVER (2) and tighten to ensure vandal-resistance.
B
C
1
REMOVE COVER
3
COUNTER-CLOCKWISE
OPENS STOP VALVE
CLOCKWISE CLOSES
STOP VALVE
2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

6247 serie

Tabla de contenido