ADJUSTING SENSOR RANGE
Note: The detection distance is preset and ideal for most
installations. Should an adjustment be required, follow the
steps below.
1. Remove the connections from the CONNECTOR LOCKING
DEVICE (5). Disconnect the 27" EXTENSION CABLE (3) from the
10' EXTENSION CABLE (4), and reconnect.
Note: You have 5 seconds to begin entering the program code
after power connection is made.
2. While the SENSOR CONTROL LED (1) is blinking
slowly, place your hand 1 to 2 in. (30-50 mm.) in front of the
sensor.
3. When the LED (1) stops blinking and stays "ON", move your hand
to the desired position from sensor and hold in place until the
LED (1) begins to blink again.
Note: Detection Zone is 400 - 800 mm (15-3/4"x 31-1/2").
(Factory Setting: 400 mm (15-3/4")
4. Once the SENSOR CONTROL LED (1) begins to blink again,
remove your hand from the detection zone. When the flashing
stops, the detection distance is set.
5. Actuate the FLUSH VALVE:
A) Cover sensor with hand for 10 seconds.
NOTE: Stand outside of sensor detection area.
B) Remove hand from detection area; unit will
flush in approximately 3 seconds.
1" - 2" (30 - 50 mm)
1
BLINKING LED
C
J
DETECTION ZONE
400 TO 800 mm (15-3/4" x 31-1/2")
(Factory Setting: 600 mm (23-5/8")
1
BLINKING LED