INSTALLATION - CONNECTION
Unisolar will divide its charge as defined above. Once the battery 1 is fully charged, the additional
current will be spread to the battery 2. Unisolar will get back to the original setting as soon as the
battery 1 is discharged.
In case that the solar charge controller only detects one battery, the whole charge will go on the
latter.
Setting 90% / 10% (factory setting):
This setting is perfect for camper van and boats. The house battery (battery 1) needs to be
recharged to the maxium whereas the started battery just needs a servicing charge to maintain its
charge.
Select your pulsation frequency:
By default, this frequency is set to 25 Hz. If you wish, you can modify this
frequency to avoid possible interferences with your other electronic devices which
use the same frequency.
- Press the button to activate the mode
- Press the button for 5 seconds to enter the menu. The number starts blinking.
- Press the button to choose the figure corresponding to the desired frequency
Connect your photovoltaic panel to the solar charge controller (+ and -)
In case of disconnection, follow the opposite order.
NB : Grounding of the solar charge controller is not necessary. If you do want ground your installation,
always do it on the positive cables.
Figure
Frequency
0
25 Hz (factory setting)
1
50 Hz
2
100 Hz
www.uniteck.fr